background image

Figure 1: 560FSD20

Figure 2: 500FSD20 Front plate

Figure 3: 500FSD20

Label

X1

X3

X2

1 2 3

1 2 3 4

Connect DIN-rail to

Protection earth

1

.

.

.

8

Figure 4: Schematic installation drawing

NF2a

NF2b

NF1a

NF1b

Z

0

Z

0

A1

A1

E1

E1

A2

A2

E2

E2

S

P

T-T

T-R

NF1

NF2

OVP

OVP

Figure 5: Communication line connection by LF transformer (two-wire connection)

Содержание EDS 500FSD20

Страница 1: ... to DTE X2 The RJ 45 connector X2 forms an RS 232 D interface If the modem is connected to an RTU an adapter cable has to be used which connects the pin pairs Pin allocation serial interface DTE RJ 45 RS 232 D Pin Signal V 24 Signal V 28 Direction 8 1 1 DSR M1 107 output Pin allocation serial interface DTE RJ 45 2 DCD M5 109 output 3 DTR S1 108 2 input 4 GND GND 5 RxD C2 104 output 6 TxD D1 103 in...

Страница 2: ...ed via Con0 off No alarm flash Warning or configuration error Alarm Alarm red Alarm Configuration using a serial configuration cable The serial interface provides access to the command line Using a serial configuration cable 500CAB06 1KGT038912R0001 the device can be connected to a serial port of a PC notebook The default configuration for the serial connection is 57600 Baud 8N1 8 data bits no par...

Страница 3: ...e restart ADVICE The established communication connection will be lost temporarily during restart Firmware Update The firmware is updated by transferring a firmware image to the device This is accomplished by first pressing the reset button for longer than 5 seconds to put the modem into firmware update mode Then with CON0 of the modem connected to a PC via a serial cable open a command window in ...

Страница 4: ... 3 to the negative terminal of a DC power supply The communication line can be either connected in two wire or four wire configuration For two wire configuration connect terminal X3 1 and X3 2 to the pair of wires For four wire configuration connect terminal X3 1 and X3 2 to the pair of wires used for transmit direction and X3 3 and X3 4 to the pair used for receive direction The internal transfor...

Страница 5: ...0 Label X1 X3 X2 1 2 3 1 2 3 4 Connect DIN rail to Protection earth 1 8 Figure 4 Schematic installation drawing NF2a NF2b NF1a NF1b Z0 Z0 A1 A1 E1 E1 A2 A2 E2 E2 S P T T T R NF1 NF2 OVP OVP Figure 5 Communication line connection by LF transformer two wire connection ...

Страница 6: ...ontents of this document without prior notice With regard to purchase orders the agreed particulars shall prevail ABB Power Grids Germany AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document We reserve all rights in this document and in the subject matter and illustrations contained therein Any reproduction disclosure to third parti...