![ABB EAS822 Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/abb/eas822/eas822_operating-instruction_3045242025.webp)
EAS822, EBS852, EBS862
ELECTRONIC UNIT | OI/EAS822/EBS852/EBS862-EN REV. D
25
Electrical data for inputs and outputs
Power supply
EAS822
Supply voltage (standard actuators)
115 V AC (94 to 130 V) or 230 V AC (190 to 260 V); 47.5 to 63 Hz; single-phase
Power consumption
50 / 160 W
Average power loss P
avg
and power consumption I
max
of
the electronic unit
Actuator
P
avg
l
max
at 115 V
l
max
at 230 V
l
pos
(115 V + 230 V):
approx. 40 to 50 % of l
max
PME120-AN
60 W
1.0 / 1.4 A*
0.5 / 0.7 A*
LME620-AN
60 W
1.0 / 1.4 A*
0.5 / 0.7 A*
External fuse for electronic unit
16 A, time-lag
External fuse for heating (dewing protection)
2 to 6 A, medium time-lag
* For low-temperature version
EBS852
Supply voltage (standard actuators)
115 V AC (94 to 130 V) or 230 V AC (190 to 260 V); 47.5 to 63 Hz; single-phase
Supply voltage (Ex actuators)
115 V AC (94 to 127 V) or 230 V AC (190 to 253 V); 47.5 to 63 Hz; single-phase
Average power loss P
avg
and power consumption I
max
of the electronic unit
Actuator
P
avg
l
max
at 115 V
l
max
at 230 V
l
pos
(115 V + 230 V):
approx. 40 to 50 % of l
max
RHD(E)250-10
60 W
1.8 A
0.9 A
RHD(E)500-10
75 W
2.2 A
1.1 A
RHD(E)800-10
60 W
5.0 A
2.5 A
RHD(E)1250-12
80 W
5.0 A
2.5 A
RHD(E)2500-25
80 W
5.0 A
2.5 A
RHD(E)4000-40
80 W
5.8 A
2.7 A
RHD(E)8000-80
80 W
5.0 A
2.5 A
RSD(E)10-5,0
55 W
2.2 A
1.1 A
RSD(E)10-10,0
60 W
3.6 A
1.8 A
RSD(E)20-5,0
60 W
3.6 A
1.8 A
RSD(E)20-7,5
75 W
4.8 A
2.4 A
RSD(E)50-3,0
75 W
5.0 A
2.5 A
RSD100-1.5
75 W
5.0 A
2.5 A
External fuse for electronic unit
16 A, time-lag
External fuse for heating (dewing protection)
2 to 6 A, medium time-lag