ABB DODGE PARA-FLEX Скачать руководство пользователя страница 3

3

Table 1 - Mounting Dimensions

Coupling Size

Clamp Ring Screw Wrench Torque (lb-in)

Distance Between Flanges

B (in)

Total Difference 

See Figure 8 (below)

C (in)

Flange Style 

Two-Piece

Flange Style 

Three-Piece

PX40 

130 

130 

49/64 

1/64

PX50 

130 

130 

31/32 

1/64

PX60 

290 

290 

1-9/32 

1/64

PX70 

290 

290 

1-1/2 

1/64

PX80 

290 

290 

1-1/2 

1/64

PX90 

480 

480 

1-17/32 

1/32

PX100 

480 

480 

1-23/32 

1/32

PX110 

480 

480 

1-9/16 

1/32

PX120 

1080 

1080 

1-3/4 

1/32

PX140 

1080 

1080 

2-1/16 

1/32

PX160 

2160 

1150 

2-11/16 

1/16

PX200 

2160 

2400 

3-5/16 

1/16

PX240 

3600 

4020 

3-29/32 

1/16

PX280 

4320 

6600 

4-7/32 

1/16

PX320 

4320 

6600 

4-1/2 

1/16

Coupling Size

Clamp Ring Screw Torque (Nm)

Thread Size

Flange Style 

Two-Piece

Flange Style

Three-Piece 

Distance Between 

Flanges "B" (mm)

Total Difference 

"C" (mm)

PXM 40

M6 

15

15

19.4

0.4

PXM 50

M6

15

15

24.6

0.4

PXM 60

M8

36

36

32.5

0.4

PXM 70

M8

36

36

38.1

0.4

PXM 80

M8

36

36

38.1

0.4

PXM 90

M10

72

72

38.9

0.8

PXM 100

M10

72

72

43.7

0.8

PXM 110

M10

72

72

39.7

0.8

PXM 120

M12

125

125

44.5

0.8

PXM 140

M12

125

125

52.4

0.8

PXM 160

M16

311

130

68.3

1.6

PXM 200

M16

311

271

84.1

1.6

Table 2 - Set Screw Torque

 Inch Set Screw Size

#0

#1

#2

#3

#4

#5

#6

#8

#10

 1/4

 5/16

 3/8

 7/16

 1/2

 9/16

 5/8

 3/4

 7/8

Torque (lb-in)

1

1.8

1.8

5

5

10

10

20

36

87

165

290

430

620

1325

2400

5200

7200

Torque (Nm)

0.1

0.2

0.2

0.6

0.6

1.1

1.1

2.3

4.1

9.8

18.6

32.8

48.6

70.1

149.7 271.2 587.5 813.5

Metric Set Screw Size

M4 

M5 

M6 

M8 

M10 

M12 

M16 

M20 

Torqe (in-lbs)

19

35

64

150

290

480

1190

2100

Installation Torque (Nm)

2.2

4

7.2

17

33

54

134

237

ATEX Approved PARA-FLEX Couplings

These instructions do not cover all details or variations in 

equipment nor provide every possible contingency or hazard 

to be met in connection with installation, operation, and 

maintenance. Should further information be desired, or should 

particular problems arise which are not covered in this manual, 

the matter should be referred to your local ABB representative.
DODGE Elastomeric couplings are manufactured under the 

guidelines of the ATEX directive 2014/34/EU.
DODGE Elastomeric couplings are suitable for ATEX category 

2 and M2, Group II and I for gas and dust environments 

and are also suitable for ATEX category 3 for all gas or dust 

environments with ignition temperatures higher than T5 = 100° 

C.
A sticker indicating ATEX certification will be attached to the 

product or on the box containing the product and will be similar 

to the following:

OR

Figure 9 - ATEX Certification

WARNING: These couplings are designed to operate with surface 

temperatures below 100°C when properly installed and selected.  

Excessive temperatures greater than 80°C is a result of an 

abnormal operating condition caused by:

1.  Improper installation - refer to installation manual for 

proper procedures

2.  Excessive misalignment - re-align coupling / shafts

3.  Failure of the coupling element - replace elastomeric

4.  Excessive speed - re-evaluate application and selection

5.  Excessive vibration - determine source, re-evaluate 

application

If applied in a Division 1 or Zone 1 environment, the excessive 

temperature may cause ignition of hazardous materials.

Содержание DODGE PARA-FLEX

Страница 1: ...ndicators or laser equipment If precision equipment is not available scales straight edges and calipers can be used as less accurate means of alignment If using a scale or calipers refer to Figure 3 and check the angular misalignment by measuring dimension B at four places 90 apart Adjust the equipment until the four measurements do not vary more than value C in Table 1 If using a straight edge ch...

Страница 2: ...ch clamp ring screw are engaged Re align flanges and install new flexible element according to the sections on flange installation and flexible element installation When replacing clamp ring screws and washers use only SAE Grade 8 or ISO Class 10 9 screws and hardened washers WARNING The metal components of the coupling that clamp the flexible element will operate properly only if the screws are t...

Страница 3: ...4 150 290 480 1190 2100 Installation Torque Nm 2 2 4 7 2 17 33 54 134 237 ATEX Approved PARA FLEX Couplings These instructions do not cover all details or variations in equipment nor provide every possible contingency or hazard to be met in connection with installation operation and maintenance Should further information be desired or should particular problems arise which are not covered in this ...

Страница 4: ...is the desired unit for use as it has design capability of accepting this movement up to 5 16 Couplings are not intended to be used as thrust bearing members 7 Coupling guards should have a minimum of 2 clearance over PARA FLEX tire style couplings 3 clearance for PARA FLEX style couplings greater than 16 outer diameter 8 The date code should be read as 14 Indicates Year Indicates Month one dot pe...