0x1A
0x0C04
0x0C06(slave)
0x0000
0x4003
0x0000
0x0008(180 degree)
0x1C
0x0C04
0x0C06(slave)
0x0000
0x6003
0x0000
0x000C(270 degree)
0x1E
N/A
N/A
N/A
N/A
N/A
N/A
•
0x10,0x16,0x18,0x1E are not populated
•
0x12 is the master device, the rest devices are slave.
•
0x12 has a phase ID of 0, 0x14
has a phase ID of 1…
•
All devices are group to Rail 0
•
Total 4-phase is configured together for Rail 0
•
0x12 has a phase angle of 360 degree, 0x14 has a phase angle of 90
degree…
•
Refer to DJT090 datasheet to modify DDC_GROUP, the default value can work in parallel
•
In general, any device within the same DDC_GROUP must have unique rail ID.
Q&A
Q: Is remote sensing supported?
A: No, optimized sense point is chosen. All measurement is based on this point. Refer to PCC location.
Q: How to connect ring connector?
A: Use one nut as a space to the board, use the other one to fasten the connection.
Q: My DC load do
esn’t sink the target current, why?
A: Check your DC load manual for minimum voltage for conducting target current. e.g. Chroma
63640-80-80 typical min operating voltage (DC) is 0.4V@80A.
Q: How to conduct full load at low output voltage?
A: Cable voltage drop is recommended to control under 0.2V.
Q: How to use DPI-CLI script?
A: Under DPI-CLI installing folder, create a txt file. Copy/paste the example script in the txt file. In
DPI-CLI command line, enter
“
i Filename.txt
”.