![ABB DCS880 series Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/abb/dcs880-series/dcs880-series_service-manual_3341016.webp)
16
Fault Tracing Thyristors
3ADW000488R0101 DCS880 Service manual e a
Fault Tracing Thyristors
Tools
For commissioning and fault tracing
Following software tools are mandatory:
−
Drive composer
pro
. Includes commissioning wizard, Adaptive Program and fast drive monitoring.
Following tools are mandatory in addition to standard tools:
−
An oscilloscope including memory function with either galvanically isolating transformer or isolating
amplifier (probe) for safe measurements. It can also be a hand held (portable) oscilloscope.
−
A clamp on current probe. In case the scaling of the DC load current needs to be checked it must be a
DC clamp on current probe.
−
A voltmeter (at least CAT III 1000 V).
−
1000 V probes and test leads.
−
An ESD-field service kit (ABB Service Finland
code 0001ESD/MS-Antistatic).
−
Make sure that all equipment in use is suitable for the voltage level applied to the power part!
Содержание DCS880 series
Страница 1: ... DCS880 DCS880 Service manual ...
Страница 46: ...46 Exchange thyristors size H6 3ADW000488R0101 DCS880 Service manual e a Location of branch fuses frame H6 ...
Страница 58: ...58 Exchange thyristors size H7 3ADW000488R0101 DCS880 Service manual e a Location of branch fuses frame H7 ...
Страница 127: ...127 Appendix Spare Parts List 3ADW000488R0101 DCS880 Service manual e a Appendix Spare Parts List ...