Operation
ABB, 1SBC159101M0201
19
7.6 Downloading an Application
Connect the RS232 port on the PC to the COM2 port on the CP410 using a
TK401 cable.
The connection can also be made according to the the illustration below:
Set the dip switch
SW7 = ON
. After the self-test, the system menu will be
displayed on the screen and the operator terminal is ready to download the
application.
Start CP400Soft and open the application file to be downloaded. Make sure that
the communication parameters are correctly configured. Also remember to
compile the file before downloading it. The file has to be compiled every time a
change has been made in the file before downloading it.
Then select
Application/Download Firmware/Application
in CP400Soft if it is
the first time to download the application to the operator terminal; otherwise,
select
Application/Download Application
. The following appears on the screen
while the operator terminal is downloading:
9-pin male
9-pin female
RXD 2
2 RD
TXD 3
3 SD
GND 5
5 SG
RTS 7
8 CTS
CTS 8
7 RTS
6 DSR
1 CD
4 DTR
Warning:
To avoid an electrical shock, be sure to switch off the power before connecting the
download cable to the operator terminal.