2-12
MN1240
Figure 2-10 Typical Connections to Feedback Termination
Motor-SSi
BSMxxx-xxxxS1 or S2
Motor-Hiperface
BSMxxx-xxxxD3 or D4
Terminal block
Power connections
BSM 90/100
Terminal block
Power connections
BSM 90/100
1
2
3
4
U
V
W
Ground
boss
Post
Function
1
Thermal switch
2
Thermal switch
3
Brake (optional)
4
Brake (optional)
U1
Motor lead U
V2
Motor lead V
W3
Motor lead W
Screw
Ground
1
2
3
4
U
V
W
Ground
boss
Post
Function
1
Thermal switch
2
Thermal switch
3
Brake (optional)
4
Brake (optional)
U1
Motor lead U
V2
Motor lead V
W3
Motor lead W
Screw
Ground
Standard motor
connector
Power connections
BSM 50/63/80 and SSBSM
Standard motor
connector
Power connections
BSM 50/63/80 and SSBSM
A
B
C
D
1
2
3
4
Post
Function
A
Thermal switch
B
Thermal switch
C
Brake (optional)
D
Brake (optional)
1
Motor lead U
2
Ground
3
Motor lead W
4
Motor lead V
A
B
C
D
1
2
3
4
Post
Function
A
Thermal switch
B
Thermal switch
C
Brake (optional)
D
Brake (optional)
1
Motor lead U
2
Ground
3
Motor lead W
4
Motor lead V
Standard SSI
connector
12 Pin
SSI connections
BSM and SSBSM
Standard hyperface
connector
12 Pin
Hyperface connections
BSM and SSBSM
1
9
8
2
10 12
7
3
11
6
4
5
Post
Function
1
+Vs (5Vdc)
2
OV
3
SSI clock
4
SSI clock
5
SSI DATA
6
SSI DATA
7
–
8
–
9
Connected to
pin 1
10
–
11
–
12
–
1
9
8
2
10 12
7
3
11
6
4
5
Post
Function
1
DATA-
2
+SIN
3
Open
4
+COS
5
OPEN
6
OPEN
7
OPEN
8
REF COS
9
US 7-12V
10
GND
11
REF SIN
12
DATA+
Note
For BSM 50/63/80 (and option on BSM90/100), the standard and rotatable power connector is rated
at 28 amps .
BSM brakes are not polarity sensitive .