2-11
MN1240
Figure 2-10 Typical Connections to Feedback Termination
Motor-BiSS
BSMxxx-xxxxB or B2
Motor-EnDat
BSMxxx-xxxxD2 or D
Terminal block
Power connections
BSM 90/100
Terminal block
Power connections
BSM 90/100
1
2
3
4
U
V
W
Ground
boss
Post
Function
1
Thermal switch
2
Thermal switch
3
Brake (optional)
4
Brake (optional)
U1
Motor lead U
V2
Motor lead V
W3
Motor lead W
Screw
Ground
1
2
3
4
U
V
W
Ground
boss
Post
Function
1
Thermal switch
2
Thermal switch
3
Brake (optional)
4
Brake (optional)
U1
Motor lead U
V2
Motor lead V
W3
Motor lead W
Screw
Ground
Standard and rotatable
connectors
Power connections
BSM 50/63/80 and SSBSM
Standard motor
connector
Power connections
BSM 50/63/80 and SSBSM
A
B
C
D
1
2
3
4
Post
Function
A
Thermal switch
B
Thermal switch
C
Brake (optional)
D
Brake (optional)
1
Motor lead U
2
Ground
3
Motor lead W
4
Motor lead V
A
B
C
D
1
2
3
4
Post
Function
A
Thermal switch
B
Thermal switch
C
Brake (optional)
D
Brake (optional)
1
Motor lead U
2
Ground
3
Motor lead W
4
Motor lead V
Standard BiSS
connector
12 Pin
BiSS connections
BSM and SSBSM
Standard EnDat
connector
12 Pin
EnDat connections
BSM and SSBSM
1
9
8
2
10 12
7
3
11
6
4
5
8Post
Function
1
DATA-
2
A+ (SIN+)
3
OV sensor
4
B+ (COS+)
5
Clock-
6
–
7
Clock+
8
B- (COS-)
9
5V & up sense
10
OV DGND
11
A- (SIN-)
12
DATA+
1
9
8
2
10 12
7
3
11
6
4
5
Post
Function
1
DATA-
2
SIN A+
3
OV sensor
4
COS B+
5
Clock-
6
5V sensor
7
Clock+
8
COS B-
9
+5V
10
DGND
11
SIN A-
12
DATA+
Note
For BSM 50/63/80 (and option on BSM90/100), the standard and rotatable power connector is rated
at 28 amps .
BSM brakes are not polarity sensitive .