Thank you for purchasing the Baldor BC154/BCWD140 Series NEMA-4X (IP-65) SCR DC Motor Speed 

and Torque Control. It is designed for applications requiring washdown watertight integrity.  

Its housing is ruggedly constructed of die cast aluminum which is protected with an acrylic coating 

for the ultimate in corrosion resistance. All switches are sealed with rubber boots and the main speed 

potentiometer has a shaft seal. 
Short circuit and transient protection are provided for ultimate in reliability. Electronic overload 

protection prevents motor burnout and demagnetization of PM motors. The control can be operated 

in either the Speed or Torque mode via jumper selection. The current range, which is also jumper 

selectable, eliminates the necessity for calibration of IR Compensation and Current Limit for most 

applications. AC line voltage 230/115VAC (jumper selectable), DC armature voltage (180/90VDC) and 

feedback type may be Armature/Tachometer.
Standard features include armature fusing (fuse sold separately), electronic start/stop switch, and 

an LED indicator array for Power On, Stop and Overload. Although factory set for most applications, a 

variety of trim pots allow adjustments of parameters.

SAFETY NOTICE

A Warning statement indicates a potentially hazardous situation which, if not avoided, could result in 

injury or death.
A Caution statement indicates a potentially hazardous situation which, if not avoided, could result in 

damage to property.
A Note indicates additional information that is not critical to the installation or operation.

WARNING:  This equipment may contain voltages as high as 1000 volts! Electrical shock can cause serious or 

fatal injury. Only qualified personnel should attempt the start-up procedure or troubleshoot this 

equipment.

WARNING:  Be sure the system is properly grounded before applying power. Do not apply AC power before you 

ensure that all grounding instructions have been followed. Electrical shock can cause serious or fatal 

injury.

WARNING:  Electrical shock can cause serious or fatal injury. Be sure that all power is disconnected and there is 

no voltage present from this equipment or equipment to which it is or will be connected. Electrical 

shock can cause serious or fatal injury. Only qualified personnel should attempt the installation and 

start-up procedures.

WARNING:  This unit has an automatic restart feature that will start the motor whenever input power is applied 

and a RUN (FWD or REV) command is issued. If an automatic restart of the motor could cause injury to 

personnel, the automatic restart feature should be disabled.

WARNING:  If possible, do not adjust trim pots with the main power applied. Electrical shock can cause serious or 

fatal injury. If adjustments are made with the main power applied, an insulated adjustment tool must 

be used to prevent shock hazard and safety glasses must be worn.

WARNING:  Do not use this drive in an explosive environment. An explosion can cause serious or fatal injury.  

This drive is not explosion proof.

WARNING:  When the Enable jumper is installed, the drive and motor will start and run when AC power is applied, 

when power is restored after a momentary power loss, or after an overload or TCL fault is reset. The 

user must ensure that automatic start up of the driven equipment will not cause injury to operating 

personnel or damage to the driven equipment. The user is responsible for providing suitable audible or 

visual alarms or other devices to indicate that the drive may start at any moment. Failure to observe 

this warning could result in severe bodily injury or loss of life.

WARNING:  Do not use start/stop, inhibit or enable functions as a safety disconnect. Use only an AC line 

disconnect for that purpose. Failure to observe this warning could result in severe bodily injury or loss 

of life.

Caution:   Disconnect motor leads (A1 and A2) from control before you perform a Dielectric Withstand test on the 

motor. Failure to disconnect motor from the control will result in extensive damage to the control. The 

control is tested at the factory for high voltage / leakage resistance as part of Underwriter Laboratory 

requirements.

Содержание BALDOR BC155

Страница 1: ...6 15 Installation Operating Manual MN702 DC SCR Drives for BC155...

Страница 2: ...Any trademarks used in this manual are the property of their respective owners Important Be sure to check www baldor com to download the latest version of this manual in Adobe Acrobat PDF format...

Страница 3: ...onnection 2 2 Field Connection 2 2 Control Circuit Wiring 2 2 Speed Potentiometer Connection 2 2 Enable 2 2 Inhibit 2 2 DC Tachometer Connection 2 2 Armature Switching Dynamic Braking 2 3 Start up and...

Страница 4: ...ii MN702...

Страница 5: ...k can cause serious or fatal injury WARNING Electrical shock can cause serious or fatal injury Be sure that all power is disconnected and there is no voltage present from this equipment or equipment t...

Страница 6: ...imum speed above the rated motor RPM since unstable motor operation may occur Receiving Each control is thoroughly tested at the factory and carefully packaged for shipment When you receive your contr...

Страница 7: ...is 40 C 104 F The WATTS LOSS value of the control at full load is 60 watts Electrical Connections Connection terminals are shown in Figure 2 1 Figure 2 1 Connection Diagrams AC Line 50 60 Hz Armature...

Страница 8: ...d the drive and motor will start and run when AC power is applied when power is restored after a momentary power loss or after an overload or TCL fault is reset The user must ensure that automatic sta...

Страница 9: ...If a 20 Volts 1000 RPM tachometer is used with a 3600 RPM motor RT 1 3 X 20 X 3600 16000 77600 Ohms Choose the closest standard watt resistor value which in this case would be 75000 Ohms 75 K ARMATUR...

Страница 10: ...crease the maximum speed rotate the MAX trimpot clockwise To decrease the maximum speed rotate the MAX trimpot counterclockwise Note The MAX trimpot is inoperative in the voltage following mode Cautio...

Страница 11: ...he ammeter rotate the CL trimpot clockwise until the desired current torque value is obtained If using an AC ammeter the measured current value will be approximately 75 of the DC current value Note On...

Страница 12: ...2 6 MN705...

Страница 13: ......

Страница 14: ......

Страница 15: ...SUITE 400 ROGERS MN 55374 PHONE 763 428 3633 FAX 763 428 4551 MISSOURI ST LOUIS 13678 LAKEFRONT DRIVE EARTH CITY MO 63045 PHONE 314 373 3032 FAX 314 373 3038 KANSAS CITY 9810 INDUSTRIAL BLVD LENEXA KS...

Страница 16: ...P O Box 2400 Fort Smith AR 72902 2400 U S A Ph 1 479 646 4711 Fax 1 479 648 5792 International Fax 1 479 648 5895 www baldor com Baldor Electric Company MN702 All Rights Reserved Printed in USA A4022...

Отзывы: