Parameters and firmware blocks
176
Firmware block:
TORQ REF MOD
(33)
This block
• selects the source for the torque
reference
• scales the input torque reference
according to the defined load share
factor
• defines limits for the torque
reference
• defines ramp-up and ramp-down
times for the torque reference
• shows the ramped torque reference
value and the torque reference
value limited by the rush control.
Block outputs located in other
parameter groups
(page
)
(page
)
32.03
TORQ REF IN
(see above)
Selects the source for the torque reference input for the torque ramp function. The default value is
P.3.9, ie, signal
, which is the output of the
firmware block.
Value pointer: Group and index
32.04
MAXIMUM TORQ REF
(see above)
Defines the maximum torque reference.
0…1000%
Maximum torque reference.
32.05
MINIMUM TORQ REF
(see above)
Defines the minimum torque reference.
-1000…0%
Minimum torque reference.
32.06
LOAD SHARE
(see above)
Scales the external torque reference to a required level (external torque reference is multiplied by the
selected value).
Note:
If local torque reference is used, no load share scaling is applied.
-8…8
External torque reference multiplier.
32.07
TORQ RAMP UP
(see above)
Defines the torque reference ramp-up time, ie, the time for the reference to increase from zero to the
nominal motor torque.
0…60 s
Torque reference ramp-up time.
TORQ REF MOD
2
TRQ REF 500 μsec
(2)
< 32.03 TORQ REF IN
[ TO RQ REF1 ]
(8 / 3.09)
32.04 MAXIMUM TORQ REF
(Drive value)
32.05 MINIMUM TORQ REF
(Drive value)
32.06 LOAD SHARE
(Drive value)
32.07 TORQ RAMP UP
(Drive value)
32.08 TORQ RAMP DOWN
(Drive value)
32.09 RUSH CTRL GAIN
(Drive value)
32.10 RUSH CTRL TI
(Drive value)
3.10 TORQ REF RAMPED
3.11 TORQ REF RUSHLIM
Содержание ACSM1 Series
Страница 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Страница 4: ......
Страница 34: ...Drive programming using PC tools 34 ...
Страница 86: ...Drive control and features 86 ...
Страница 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Страница 302: ...Parameter data 302 ...
Страница 422: ...Application program template 422 ...
Страница 430: ...Appendix A Fieldbus control 430 ...
Страница 500: ...Appendix D Application examples 500 ...
Страница 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Страница 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...