Parameters 333
Displays the energy saved in MWh compared to direct-on-line
motor connection. This parameter is incremented when
rolls over.
When this parameter rolls over, parameter
is incremented.
This parameter is read-only (see parameter
-
0…999 MWh
Energy savings in MWh.
1 = 1 MWh
Displays the energy saved in kWh compared to direct-on-line
motor connection.
If the internal brake chopper of the drive is enabled, all energy
fed by the motor to the drive is assumed to be converted into
heat, but the calculation still records savings made by
controlling the speed. If the chopper is disabled, then
regenerated energy from the motor is also recorded here.
When this parameter rolls over, parameter
is incremented.
This parameter is read-only (see parameter
-
0.0 … 999.9 kWh
Energy savings in kWh.
10 = 1 kWh
Displays the monetary savings in thousands compared to
direct-on-line motor connection. This parameter is
incremented when
rolls over.
The currency is defined by parameter
.
This parameter is read-only (see parameter
-
0…4294967295
thousands
Monetary savings in thousands of units.
-
Displays the monetary savings compared to direct-on-line
motor connection. This value is a calculated by multiplying the
saved energy in kWh by the currently active energy tariff
(
).
When this parameter rolls over, parameter
is incremented.
The currency is defined by parameter
.
This parameter is read-only (see parameter
-
0.00 … 999.99 units Monetary savings.
1 = 1 unit
Displays the reduction in CO
2
emissions in metric kilotons
compared to direct-on-line motor connection. This value is
incremented when parameter
rolls over.
This parameter is read-only (see parameter
-
0…65535 metric
kilotons
Reduction in CO
2
emissions in metric kilotons.
1 = 1 metric
kiloton
No.
Name/Value
Description
Def
/
FbEq16
Содержание ACS880-x04
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 primary control program Firmware manual ...
Страница 4: ......
Страница 18: ...18 Using the control panel ...
Страница 24: ...24 Control locations and operating modes ...
Страница 111: ...Application macros 111 Fieldbus control macro This application macro is not supported by the current firmware version ...
Страница 112: ...112 Application macros ...
Страница 496: ...496 Additional parameter data ...
Страница 544: ...544 Fault tracing ...
Страница 602: ...602 Control chain diagrams ...