Signals and parameters 37
DI1
Start Decanter through DI1.
2
DI2
Start Decanter through DI2.
3
DI3
Start Decanter through DI3.
4
DI4
Start Decanter through DI4.
5
DI5
Start Decanter through DI5.
6
DI6
Start Decanter through DI6.
7
Comm CW
Fieldbus communication control word.
8
Bowl drive
The scroll reads the control word Start/Stop command
from the bowl.
9
-
78.04
Delta speed
function
Selects differential speed direction (only in scroll drive).
Forward drive
Forward drive
Forward drive. Scroll speed > Bowl speed.
0
Backward drive
Backward drive. Scroll speed < Bowl speed.
1
78.05
Delta speed ref
selection
Selects differential speed reference (delta speed) of
Decanter Control.
AI1 scaled
Zero
Zero
0
AI1 scaled
Analog input 1 scaled.
1
AI2 scaled
Analog input 2 scaled.
2
Comm ref 1
Fieldbus communication reference 1.
3
D Speed ref
Differential speed reference. See
4
-
78.06
Delta speed
reference
Defines differential speed (delta speed).
0.00 rpm
0...1500.00 rpm
Differential speed.
-
78.07 Bowl belt D1
Defines mechanical drive factor of bowl motor belt roller
D1.
1.00
-1000.00...1000.00
Bowl belt D1 mechanical drive factor.
-
78.08 Bowl belt D2
Defines mechanical drive factor of bowl motor belt roller
D2.
1.00
-1000.00...1000.00
Bowl belt D2 mechanical drive factor.
-
78.09
Gearbox ratio
Defines gearbox ratio of Decanter.
1.00
-1000.00...1000.00
Decanter gearbox ratio.
-
Parameters
No
Name/Value
Description
Def
/
FbEq16