Speed controller autotune
The speed controller of the drive can be automatically adjusted using the autotune
function. Autotuning is based on an estimation of the mechanical time constant
(inertia) of the motor and machine.
The autotune routine will run the motor through a series of
acceleration/deceleration cycles, the number of which can be adjusted by
parameter
. Higher values will produce more accurate results, especially if
the difference between initial and maximum speeds is small.
The maximum torque reference used during autotuning will be the initial torque
(ie. torque when the routine is activated) plus
, unless limited by the maximum
torque limit (parameter group
) or the nominal motor torque (parameter
group
). The calculated maximum speed during the routine is the
initial speed (ie. speed when the routine is activated) +
, unless limited by
parameter
or
The diagram below shows the behavior of speed and torque during the autotune
routine. In this example,
is set to 2.
Initial
[
25.38
]
Initial torque
Initial speed +
[
25.39
]
Initial speed
t
Program features 79