Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
0 = Nm (N·m)
1 = lbft (lbf·ft)
Torque unit
b4
Reserved
b5…15
1 = 1
0000h…FFFFh
DDCS Controller /
uint16
Defines the 1st priority external source for
synchronization of the drive's time and date.
The date and time can also be directly set into
…
in which case this parameter is ignored.
Time sync primary
source
96.20
0
No external source selected.
Internal
1
External controller.
DDCS Controller
2
Fieldbus interface A or B.
Fieldbus A or B
3
Fieldbus interface A.
Fieldbus A
4
Fieldbus interface B.
Fieldbus B
5
The master station on a master/follower or
drive-to-drive link.
D2D or M/F
6
Embedded fieldbus interface.
Embedded FB
8
Control panel, or Drive Composer PC tool connected
to the control panel.
Panel link
9
Drive Composer PC tool through an FENA module.
Ethernet tool link
Inactive / uint16
In the master drive, activates clock synchronization for
master/follower and drive-to-drive communication.
M/F and D2D clock
synchronization
96.23
0
Clock synchronization not active.
Inactive
1
Clock synchronization active.
Active
- / uint16
Number of full days passed since beginning of the year
1980. This parameter, together with
and
makes it possible to set the date and time in
the drive via the parameter interface from a fieldbus
or application program. This may be necessary if the
fieldbus protocol does not support time
synchronization.
Full days since 1st
Jan 1980
96.24
1 = 1 days / 1 = 1 days
Days count. 1 = 1st January 1980.
1...59999 days
0 min / uint16
Number of full minutes passed since midnight. For
example, the value 860 corresponds to 2:20 pm.
See parameter
96.24 Full days since 1st Jan 1980
Time in minutes
within 24 h
96.25
1 = 1 min / 1 = 1 min
Minutes since midnight.
0...1439 min
0 ms / uint16
Number of milliseconds passed since last minute.
See parameter
96.24 Full days since 1st Jan 1980
Time in ms within
one minute
96.26
1 = 1 ms / 1 = 1 ms
Number of milliseconds since last minute.
0...59999 ms
- / uint16
Time source status word.
Note: This parameter is read-only.
Time sync source
status
96.29
1 = 1st priority tick received: Tick has been received
from 1st priority source (or from
…
).
Time tick received
b0
Parameters 521
Содержание ACS880 N5700 Series
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 position control program N5700 Firmware manual ...
Страница 2: ......
Страница 4: ......
Страница 22: ...22 ...
Страница 28: ...28 ...
Страница 32: ...32 ...
Страница 60: ...60 ...
Страница 456: ...Def Type FbEq 16b 32b Description Name Range Selection No 100 1 1 1 Overriding value 0 001 100 000 456 Parameters ...
Страница 546: ...546 ...
Страница 604: ...604 ...
Страница 626: ...626 ...
Страница 640: ...640 ...
Страница 660: ...660 ...