Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
Yes / uint16
Enables/disables detection of encoder drift, ie. slippage
between the encoder and the shaft. The function is
designed to detect erroneous feedback in static
operating conditions.
However, because of limitations in estimating the
motor speed, drift detection must be disabled or will
be internally ignored in the following circumstances:
•
Motor model is not operative (drive is not
modulating, ID run is in progress, or motor is
coasting)
•
Estimated motor speed has not settled (motor
start time delay has not elapsed).
•
Estimated motor speed is below 50 rpm
•
Speed error (encoder speed - estimated motor
speed) is below 100 rpm, and
•
During high dynamic motion with the speed
reference changing rapidly.
Enable motor
encoder drift
detection
90.47
0
Drift detection disabled.
No
1
Drift detection enabled.
Yes
100.00 rpm / int32
Defines a supervision limit for the difference between
actual load encoder speed (scaled to motor axis as
rpm) and actual motor speed. If the difference remains
above this limit for longer than the time set in
, the drive trips on
, and the motor stops according
to
Load speed
supervision delta
90.97
1 rpm / 1 = 1 rpm
Limit for encoder/motor speed difference.
0.00 ... 3000.00 rpm
300 ms / int32
Defines a delay for encoder/motor speed difference
supervision. See
90.98 Load speed supervision delay
Load speed
supervision delay
90.98
1 ms / 1 = 1 ms
Speed difference supervision delay.
0...10000 ms
488 Parameters
Содержание ACS880 N5700 Series
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 position control program N5700 Firmware manual ...
Страница 2: ......
Страница 4: ......
Страница 22: ...22 ...
Страница 28: ...28 ...
Страница 32: ...32 ...
Страница 60: ...60 ...
Страница 456: ...Def Type FbEq 16b 32b Description Name Range Selection No 100 1 1 1 Overriding value 0 001 100 000 456 Parameters ...
Страница 546: ...546 ...
Страница 604: ...604 ...
Страница 626: ...626 ...
Страница 640: ...640 ...
Страница 660: ...660 ...