Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
- / uint16
Selects the followers (out of followers 17…32) whose
status words are monitored by the D2D master.
Note: Also activate communication supervision for the
same followers in parameter
See parameter
60.23 M/F status supervision sel 1
.
M/F status
supervision sel 2
60.24
1 = Status of follower 17 is monitored.
Follower 17
b0
1 = Status of follower 18 is monitored.
Follower 18
b1
1 = Status of follower 19 is monitored.
Follower 19
b2
1 = Status of follower 20 is monitored.
Follower 20
b3
1 = Status of follower 21 is monitored.
Follower 21
b4
1 = Status of follower 22 is monitored.
Follower 22
b5
1 = Status of follower 23 is monitored.
Follower 23
b6
1 = Status of follower 24 is monitored.
Follower 24
b7
1 = Status of follower 25 is monitored.
Follower 25
b8
1 = Status of follower 26 is monitored.
Follower 26
b9
1 = Status of follower 27 is monitored.
Follower 27
b10
1 = Status of follower 28 is monitored.
Follower 28
b11
1 = Status of follower 29 is monitored.
Follower 29
b12
1 = Status of follower 30 is monitored.
Follower 30
b13
1 = Status of follower 31 is monitored.
Follower 31
b14
1 = Status of follower 32 is monitored.
Follower 32
b15
1 = 1
0000h…FFFFh
- / uint16
In the D2D master, parameters
and
60.28 M/F status supv mode sel 2
specify the mode of follower status word monitoring.
Each follower can individually be set to be monitored
continuously, or only when it is in stopped state.
This parameter selects the mode of status word
monitoring of followers 1…16.
M/F status supv
mode sel 1
60.27
0 = Status of follower 1 is monitored continuously.
1 = Status of follower 1 is monitored only when it is in
stopped state.
Follower 1
b0
0 = Status of follower 2 is monitored continuously.
1 = Status of follower 2 is monitored only when it is in
stopped state.
Follower 2
b1
0 = Status of follower 3 is monitored continuously.
1 = Status of follower 3 is monitored only when it is in
stopped state.
Follower 3
b2
0 = Status of follower 4 is monitored continuously.
1 = Status of follower 4 is monitored only when it is in
stopped state.
Follower 4
b3
Parameters 413
Содержание ACS880 N5700 Series
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 position control program N5700 Firmware manual ...
Страница 2: ......
Страница 4: ......
Страница 22: ...22 ...
Страница 28: ...28 ...
Страница 32: ...32 ...
Страница 60: ...60 ...
Страница 456: ...Def Type FbEq 16b 32b Description Name Range Selection No 100 1 1 1 Overriding value 0 001 100 000 456 Parameters ...
Страница 546: ...546 ...
Страница 604: ...604 ...
Страница 626: ...626 ...
Страница 640: ...640 ...
Страница 660: ...660 ...