Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
1 = 10 / 100 = 1
Scaled reference 2 received from external controller.
-30000.00 ...
30000.00
- / real32
Master/follower reference 1 received from the master.
The value has been scaled according to parameter
See also section
M/F or D2D ref1
3.13
1 = 10 / 100 = 1
Scaled reference 1 received from master.
-30000.00 ...
30000.00
- / real32
Master/follower reference 2 received from the master.
The value has been scaled according to parameter
M/F or D2D ref2
3.14
1 = 10 / 100 = 1
Scaled reference 2 received from master.
-30000.00 ...
30000.00
- / int32
Reference 1 received through fieldbus adapter A as a
32-bit integer.
FB A reference 1
int32
3.30
- / -
Reference 1 from fieldbus adapter A.
-2147483648...2147483647
- / int32
Reference 2 received through fieldbus adapter A as a
32-bit integer.
FB A reference 2
int32
3.31
- / -
Reference 2 from fieldbus adapter A.
-2147483648...2147483647
0 / real32
Panel reference defined in the application program.
IEC application
panel reference
3.51
1 = 1 / 1 = 1
Panel reference in the application program.
-100000...100000
Parameters 141
Содержание ACS880 N5700 Series
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 position control program N5700 Firmware manual ...
Страница 2: ......
Страница 4: ......
Страница 22: ...22 ...
Страница 28: ...28 ...
Страница 32: ...32 ...
Страница 60: ...60 ...
Страница 456: ...Def Type FbEq 16b 32b Description Name Range Selection No 100 1 1 1 Overriding value 0 001 100 000 456 Parameters ...
Страница 546: ...546 ...
Страница 604: ...604 ...
Страница 626: ...626 ...
Страница 640: ...640 ...
Страница 660: ...660 ...