226 Parameters
Defines a gain for the output of the oscillation damping
function, ie. how much the output of the filter is amplified
before it is added to the torque reference.
Oscillation gain is scaled according to the speed controller
gain so that changing the gain will not disturb oscillation
damping.
Note:
Before changing this parameter run-time, disable
the oscillation damping output using parameter
.
Monitor the behavior of
before re-enabling the
output.
1.0%
0.0 … 100.0%
Gain setting for oscillation damping output.
10 = 1%
Displays the output of the oscillation damping function.
This value is added to the torque reference (as allowed by
parameter
Oscillation damping out enable
).
This parameter is read-only.
-
-1600.000 …
1600.000%
Output of the oscillation damping function.
10 = 1%
Rush controller gain term. See section
(page
).
10.0
0.0 …10000.0
Rush controller gain (0.0 = disabled).
1 = 1
Rush controller integration time term.
2.0 s
0.0 …10.0 s
Rush controller integration time (0.0 = disabled).
1 = 1 s
28
Settings for the frequency reference chain.
See the control chain diagrams on pages
Displays the used frequency reference before ramping.
See the control chain diagram on page
This parameter is read-only.
-
-500.00…500.00 Hz
Frequency reference before ramping.
See par.
Displays the final frequency reference (after selection,
limitation and ramping). See the control chain diagram on
page
This parameter is read-only.
-
-500.00…500.00 Hz
Final frequency reference.
See par.
No.
Name/Value
Description
Def/
FbEq16
Содержание ACS880 ESP
Страница 1: ...ABB industrial drives Firmware manual ACS880 PCP ESP control program ...
Страница 4: ......
Страница 28: ...28 PCP ESP control start up ...
Страница 30: ...30 Using the control panel ...
Страница 94: ...94 Standard programposi features ...
Страница 100: ...100 Default control connections ...
Страница 360: ...360 Parameters ...
Страница 362: ...362 Additional parameter data Fieldbus addresses Refer to the User s Manual of the fieldbus adapter ...
Страница 436: ...436 Fault tracing ...
Страница 486: ...486 Control chain diagrams ...
Страница 492: ...492 Appendix ESP with step up transformer and sine filter ...
Страница 494: ...Contact us www abb com drives www abb com drivespartners 3AXD50000016186 Rev B EN 2015 10 27 ...