Materials
Cabinet
• Zinc coated steel sheet
• Polyester thermosetting powder coating on visible surfaces, color RAL 7035 and
RAL 9017
Tin-plated copper
Busbars for user power
connections
See
Cooling circuit materials (page 158)
Liquid cooling system
Insulating materials and non-metallic items: mostly self-extinctive
Fire safety of materials
(IEC 60332-1)
Standard package:
Package
• timber, polyethylene sheet (thickness 0.15 mm), stretch film (thickness 0.023 mm),
PP tape, PET strap, sheet metal (steel)
• for land and air transport when planned storage time is less than 2 months or
when storage can be arranged in clean and dry conditions less than 6 months
• can be used when products will not be exposed to corrosive atmosphere during
transport or storage
Container package:
• timber, VCI sheet film (PE, thickness 0.10 mm), VCI stretch film (PE, thickness
0.04 mm), VCI emitter bags, PP tape, PET strap, sheet metal (steel)
• for sea transport in containers
• recommended for land and air transport when storage time prior to installation
exceeds 6 months or storage is arranged in partially weather-protected conditions
Seaworthy package:
• timber, plywood, VCI sheet film (PE, thickness 0.10 mm), VCI stretch film (PE,
thickness 0.04 mm), VCI emitter bags, PP tape, PET strap, sheet metal (steel)
• for sea transport with or without containerization
• for long storage periods in environments where roofed and humidity-controlled
storage cannot be arranged
Cabinets are attached to the pallet with screws and braced from the top end to the
package walls to prevent swaying inside the package. Package elements are at-
tached to each other with screws.
The main parts of the drive can be recycled to preserve natural resources and en-
ergy. Product parts and materials should be dismantled and separated.
Generally all metals, such as steel, aluminum, copper and its alloys, and precious
metals can be recycled as material. Plastics, rubber, cardboard and other packaging
material can be used in energy recovery. Printed circuit boards and large electro-
lytic capacitors need selective treatment according to IEC 62635 guidelines. To
aid recycling, plastic parts are marked with an appropriate identification code.
Contact your local ABB distributor for further information on environmental aspects
and recycling instructions for professional recyclers. End of life treatment must
follow international and local regulations. See
ACS880 cabinet-installed drives re-
cycling instructions and environmental information
(3AXD50000153909 [English]).
Disposal
Applicable standards
Information
Standard
European electrical safety requirements product standards
Adjustable speed electrical power drive systems. Part 5-1: Safety requirements –
electrical, thermal and energy
IEC/EN 61800-5-1:2007
Semiconductor converters – General requirements and line commutated converters
– Part 1-1: Specification of basic requirements
IEC 60146-1-1:2009
EN 60146-1-1:2010
Insulation coordination for equipment within low-voltage systems. Part 1: Principles,
requirements and tests
IEC/EN 60664-1:2007
Technical data 179
Содержание ACS880-07LC
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 07LC drives Hardware manual ...
Страница 2: ......
Страница 4: ......
Страница 12: ...16 Resistor braking Further information 12 Table of contents ...
Страница 22: ...22 ...
Страница 63: ...Mechanical installation 63 10 ...
Страница 64: ...64 ...
Страница 91: ...a b c 4 a 8 b 16 18 PE PE 10 13 12 Electrical installation 91 11 ...
Страница 97: ...11 Reinstall the shrouding removed earlier 12 Close the cubicle door Electrical installation 97 11 ...
Страница 100: ...With FDPI 02 modules OPEN TERMIN ATED 1 1 2 2 OPEN TERMINATED 3 100 Electrical installation ...
Страница 104: ...104 ...
Страница 118: ...118 ...
Страница 124: ...124 ...
Страница 138: ...8 9 138 Maintenance ...
Страница 139: ...11 12 12 6 10 Maintenance 139 ...
Страница 150: ...150 ...
Страница 160: ...160 ...
Страница 183: ...Technical data 183 ...
Страница 184: ...184 Technical data ...
Страница 189: ... Dimension drawing examples ACS880 07LC 0850A 7 Dimensions 189 ...
Страница 190: ...ACS880 07LC 1660A 7 6 pulse 190 Dimensions ...
Страница 191: ...ACS880 07LC 1660A 7 A004 12 pulse Dimensions 191 ...
Страница 192: ...ACS880 07LC 3260A 7 192 Dimensions ...
Страница 193: ...Cabinet height and depth Marine construction option C121 IP42 side view Non marine IP42 side view Dimensions 193 ...
Страница 194: ...Location and size of input terminals 600 mm with main breaker single busbar bottom cable entry 194 Dimensions ...
Страница 195: ... 600 mm with main breaker double busbar bottom cable entry Dimensions 195 ...
Страница 197: ...Inverter module cubicle with two R8i modules bottom cable exit Dimensions 197 ...
Страница 198: ...Inverter module cubicle with three R8i modules bottom cable exit 198 Dimensions ...
Страница 199: ...Brake chopper cubicle Dimensions 199 ...
Страница 200: ...200 ...
Страница 216: ... Declaration of conformity 216 The Safe torque off function ...
Страница 217: ...The Safe torque off function 217 ...
Страница 218: ...218 ...
Страница 220: ...220 ...