402 Parameters
Selects the node address of the drive for communication with
the external controller. No two nodes on-line may have the
same address.
With an AC 800M (CI858) DriveBus connection, drives must
be addressed 1…24.
With an AC 80 DriveBus connection, drives must be
addressed 1…12.
With optical ModuleBus, the drive address is set according to
the position value as follows:
1. Multiply the hundreds of the position value by 16.
2. Add the tens and ones of the position value to the result.
For example, if the position value is 101, this parameter must
be set to 1×16 + 1 = 17.
1
1…254
Node address.
Selects the topology of the fiber optic link with an external
controller.
Ring
The devices are connected in a ring topology. Forwarding of
messages is enabled.
0
Star
The devices are connected in a star topology (for example,
through a branching unit). Forwarding of messages is
disabled.
1
Selects the communication speed of the channel selected by
parameter
1 mbps
1 megabit/second.
1
2 mbps
2 megabit/second.
2
4 mbps
4 megabit/second.
4
8 mbps
8 megabit/second.
8
Defines the light intensity of the transmission LED of RDCO
module channel CH0. (This parameter is effective only when
parameter
. FDCO modules have a hardware transmitter current
selector.)
In general, use higher values with longer fiber optic cables.
The maximum setting is applicable to the maximum length of
the fiber optic link. See
Specifications of the fiber optic
(page
).
10
1…15
Light intensity.
No.
Name/Value
Description
Def
/
FbEq16
Содержание ACS880-01 Series
Страница 1: ...ABB industrial drives Firmware manual ACS880 ESP control program option N5600 ...
Страница 4: ......
Страница 12: ...12 Table of contents ...
Страница 20: ...20 Introduction to the manual ...
Страница 22: ...22 Using the control panel ...
Страница 28: ...28 Control locations and operating modes ...
Страница 145: ...Application macros 145 Fieldbus control macro This application macro is not supported by the current firmware version ...
Страница 146: ...146 Application macros ...
Страница 502: ...502 Parameters ...
Страница 606: ...606 Fault tracing ...
Страница 662: ...662 Control chain diagrams ...
Страница 664: ...Contact us www abb com drives www abb com drivespartners 3AXD50000041193 Rev A EN EFFECTIVE 2017 06 30 ...