Parameters 305
Defines the stator resistance
R
S
of the motor model.
Resistance value is given at 20 °C.
0.00000 ohm
0.00000 …
100.00000 ohm
Stator resistance.
-
Defines the rotor resistance
R
R
of the motor model.
Resistance value is given at 20 °C.
Note:
This parameter is valid only for asynchronous motors.
0.00000 ohm
0.00000 …
100.00000 ohm
Rotor resistance.
-
Defines the main inductance
L
M
of the motor model.
Note:
This parameter is valid only for asynchronous motors.
0.00 mH
0.00 …100000.00
mH
Main inductance.
1 = 10 mH
Defines the leakage inductance
L
S
.
Note:
This parameter is valid only for asynchronous motors.
0.00 mH
0.00 …100000.00
mH
Leakage inductance.
1 = 10 mH
99
Motor configuration settings.
Selects the motor type.
Note:
This parameter cannot be changed while the drive is
running.
;
SynRM
(
95.21
b1);
Permanent
magnet
motor
(
95.21
b2)
Asynchronous
motor
Standard squirrel cage AC induction motor (asynchronous
induction motor).
0
Selects the motor control mode.
Note:
This parameter cannot be changed while the drive is
running.
Vector
Vector
Vector control. This mode is suitable for most applications.
Note:
Instead of direct torque control, scalar control is also
available, and should be used in the following situations:
• with multimotor applications 1) if the load is not equally
shared between the motors, 2) if the motors are of different
sizes, or 3) if the motors are going to be changed after the
motor identification (ID run)
• if the nominal current of the motor is less than 1/6 of the
nominal output current of the drive
• if the drive is used with no motor connected (for example,
for test purposes).
See also section
0
No.
Name/Value
Description
Def
/
FbEq16
Содержание ACS860
Страница 1: ... ABB INDUSTRIAL DRIVES ACS860 primary control program Firmware manual ...
Страница 4: ......
Страница 10: ...10 Table of contents ...
Страница 18: ...18 Using the control panel ...
Страница 24: ...24 Control locations and operating modes ...
Страница 54: ...54 Program features ...
Страница 78: ...78 Program features ...
Страница 90: ...90 Application macros ...
Страница 342: ...342 Additional parameter data ...
Страница 380: ...380 Fault tracing ...
Страница 381: ...Fault tracing 381 ...
Страница 382: ...382 Fault tracing ...
Страница 436: ...436 Control chain diagrams ...