![ABB ACS850-04 series Скачать руководство пользователя страница 165](http://html1.mh-extra.com/html/abb/acs850-04-series/acs850-04-series_firmware-manual_3365228165.webp)
Parameters 165
23.20
PI tune mode
Activates the speed controller autotune function.
The autotune will automatically set parameters
, as well as
is automatically set.
The status of the autotune routine is shown by parameter
.
WARNING!
The motor will reach the torque and
current limits during the autotune routine. ENSURE
THAT IT IS SAFE TO RUN THE MOTOR BEFORE
PERFORMING THE AUTOTUNE ROUTINE!
Notes:
• Before using the autotune function, the following
parameters should be set:
• All parameters adjusted during the start-up as described
in the
ACS850 (Standard Control Program) Quick Start-
up Guide
•
•
•
• Speed reference ramp settings in group
•
• The drive must be in local control mode and stopped
before an autotune is requested.
• After requesting an autotune with this parameter, start the
drive within 20 seconds.
• Wait until the autotune routine is completed (this parameter
has reverted to the value
). The routine can be
aborted by stopping the drive.
See also section
(page
Done
No tuning has been requested (normal operation).
The parameter also reverts to this value after an autotune is
completed.
0
Smooth
Request speed controller autotune with preset settings for
smooth operation.
1
Middle
Request speed controller autotune with preset settings for
medium-tight operation.
2
Tight
Request speed controller autotune with preset settings for
tight operation.
3
User
Request speed controller autotune with the settings defined
by parameters
4
23.21
Tune bandwidth
Speed controller bandwidth for autotune procedure,
mode (see parameter
A larger bandwidth results in more restricted speed controller
settings.
00.00 … 2000.00
Hz
Tune bandwidth for
autotune mode.
100 = 1 Hz
23.22
Tune damping
Speed controller damping for autotune procedure,
mode
(see parameter
Higher damping results in safer and smoother operation.
0.0 … 200.0
Speed controller damping for
autotune mode.
10 = 1
No.
Name/Value
Description
FbEq
Содержание ACS850-04 series
Страница 1: ...ACS850 Firmware Manual ACS850 Standard Control Program...
Страница 4: ......
Страница 10: ...10 Table of contents...
Страница 52: ...52 The ACS850 control panel...
Страница 56: ...56 Control locations and operating modes...
Страница 80: ...80 Program features...
Страница 236: ...236 Parameters...
Страница 286: ...286 Fieldbus control...
Страница 294: ...294 Control block diagrams...