102 Practical examples
Updating the firmware
1. Before updating the firmware it is recommended to create a full Backup Package of
the old firmware in RDCU and NDCU boards and save the old parameter file. For
details, see sections
Creating a full Backup Package and saving it in .BPG format
and
Saving a parameter file (.dwp) to the PC
.
2. Connect the fiber optic connectors to the board to be updated (RDCU or NDCU).
Change the node address (70.15 CH3 NODE ADDR) of the board to be updated to 1
or to the same value as the default value in the update package (11 for rotor-side
converter, 21 for grid-side converter). Download the new firmware version as
instructed in section
Restoring a backup file into the RDCU or NDCU board
.
3. Set your converter type. Do the following settings in order to access those parameters:
Rotor-side converter
16.01 PARAM LOCK to OFF
16.03 PASS CODE to 1
Grid-side converter
16.02 PARAMETER LOCK to OPEN
16.03 PASS CODE to 2303
A reboot is needed to validate the converter type selected. Switch the auxiliary voltage
off and back on.
4. Download the old parameter file that was saved in step 1. For details, see section
Downloading parameters into the converter
.
5. Force the new parameters into FLASH by selecting
Yes
.
6. If downloading of the parameters is succeeded, following note appears. Select
Yes
,
and the update is ready and the updated board is connected.
Содержание ACS800-67
Страница 1: ...ABB wind turbine converters System description and start up guide ACS800 67 wind turbine converters ...
Страница 4: ......
Страница 76: ...76 Start up with medium voltage stator ...
Страница 99: ...Practical examples 99 1 4 4 3 2 5 6 7 ...
Страница 106: ...106 Practical examples Counterclockwise rotation at drive end D end Power cabinet Encoder ...
Страница 118: ...118 Tracing the source of warnings limits and faults ...
Страница 120: ...Contact us www abb com windconverters 3AUA0000095094 Rev B EN 2017 12 31 ...