292 Parameters
Defines the maximum continuous load of the brake resistor
that will eventually raise the resistor temperature to the
maximum allowed value (= continuous heat dissipation
capacity of the resistor in kW) but not above it. The value is
used in the resistor overload protection based on the thermal
model. See parameter
the
data sheet of the brake resistor used.
0.00 kW
0.00…
10000.00 kW
Maximum continuous load of the brake resistor.
1 = 1 kW
Defines the resistance value of the brake resistor. The value
is used for the brake resistor protection based on the thermal
model. See parameter
0.0 ohm
0.0…1000.0 ohm
Brake resistor resistance value.
1 = 1 ohm
Selects the fault limit for the brake resistor protection based
on the thermal model. See parameter
. When the limit is exceeded, the drive trips on fault
.
The value is given in percent of the temperature the resistor
reaches when loaded with the power defined by parameter
105%
0…150%
Brake resistor temperature fault limit.
1 = 1%
Selects the warning limit for the brake resistor protection
based on the thermal model. See parameter
. When the limit is exceeded, the drive
generates a
warning.
The value is given in percent of the temperature the resistor
reaches when loaded with the power defined by parameter
95%
0…150%
Brake resistor temperature warning limit.
1 = 1%
44
Configuration of mechanical brake control.
See also section
Displays the mechanical brake control status word.
This parameter is read-only.
-
0000h…FFFFh
Mechanical brake control status word.
1 = 1
No.
Name/Value
Description
Def/FbEq16
Bit
Name
Information
0
Open command
Close/open command to brake actuator (0 = close, 1 = open).
Connect this bit to desired output.
1
Opening torque
request
1 = Opening torque requested from drive logic.
2
Hold stopped
request
1 = Hold requested from drive logic
3
Ramp to stopped
1 = Ramping down to zero speed requested from drive logic
4
Enabled
1 = Brake control is enabled
5
Closed
1 = Brake control logic in
state
6
Opening
1 = Brake control logic in
state
7
Open
1 = Brake control logic in
state
8
Closing
1 = Brake control logic in
state
9…15
Reserved
ACS580 FW.book Page 292 Wednesday, September 21, 2016 9:48 PM
Содержание ACS580 Series
Страница 88: ...84 ACS580 FW book Page 84 Wednesday September 21 2016 9 48 PM ...
Страница 146: ...142 Program features ACS580 FW book Page 142 Wednesday September 21 2016 9 48 PM ...
Страница 444: ...440 Fieldbus control through a fieldbus adapter ACS580 FW book Page 440 Wednesday September 21 2016 9 48 PM ...
Страница 461: ...ACS580 FW book Page 457 Wednesday September 21 2016 9 48 PM ...
Страница 462: ...3AXD0000016097 Rev D EN 2016 09 02 ACS580 FW book Page 458 Wednesday September 21 2016 9 48 PM ...