56 Actual signals and parameters
6004
PV CELL MIN
VOLT
Defines the minimum DC voltage below which the
inverter cannot operate.
Note
: The inverter stops operating below this voltage.
1 = 1 V
109...800 V
DC voltage.
Note
: Range is different for 1-phase and 3-phase
inverters.
400 V unit:
225
200 V unit:
129
6005
PV CELL MAX
VOLT
Defines the maximum DC voltage. At any value above
this voltage, the inverter trips due to
fault.
1 = 1 V
109...800 V
DC voltage.
Note
: Range is different for 1-phase and 3-phase
inverters.
400 V unit:
640
200 V unit:
368
6006
PUMP
MINIMUM SPD
Defines the minimum motor speed. At any value below
this speed, the inverter stops functioning and auto
restarts after the time defined in
. This setting avoids unnecessary operation of
pump at low speed.
1 = 1 rpm
0...3000 rpm
Speed
0
6007
PUMP
MAXIMUM SPD
Defines the maximum motor speed.
1 = 1 rpm
0...3000 rpm
Speed
3000
6008
BOOST VOLT
Defines the DC voltage above which 6009 BOOST
FACTOR is effective. Below this value, motor speed
follows the V/F factor.
1 = 1 V
109...600 V
DC voltage.
Note
: Range is different for 1-phase and 3-phase
inverters.
400 V unit:
450
200 V unit:
259
6009
BOOST
FACTOR
Defines the factor at which the inverter functions the
best. This parameter is effective when DC voltage is
above the value in 6008 BOOST VOLT.
100 = 1
0.75...1.25
Boost factor
1.00
6015
DRY RUN SEL
DI
Selects the input for dry run protection.
WITH_
P60.16
DI1
Digital input DI1. Defines the digital input DI1 as the
control for dry run protection.
1
DI2
See selection
2
All parameters
No.
Name/
Value
Description
Def/ FbEq
Содержание ACS355 series
Страница 1: ...ABB machinery drives Supplement ACS355 Solar pump inverter N827...
Страница 4: ......
Страница 10: ...10 Safety...
Страница 14: ...14 Introduction...
Страница 18: ...18 Operating principle and hardware description...
Страница 30: ...30 Start up and controls...
Страница 36: ...36 Program features...
Страница 66: ...66 Actual signals and parameters...
Страница 70: ...70 Fault tracing...
Страница 76: ...76 Technical data...
Страница 78: ...www abb com drives www abb com solar www abb com drivespartners 9ARD000864 Rev B EN 2015 02 02 Contact us...