![ABB ACS355 series Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/abb/acs355-series/acs355-series_quick-installation-manual_2973008.webp)
8 Quick installation guide – ACS355
1)
The rated fuse currents given in the table are the
maximums for the mentioned fuse types for short-
circuit protection of the input power cable. Check that
the operating time of the fuse is below 0.5 seconds. If
the 0.5 seconds operating time is exceeded with the
gG or T fuses, ultra rapid (aR) fuses will in most cases
reduce the operating time to an acceptable level.
Note:
Larger fuses must not be used when the input
power cable is selected according to this table.
2)
If 50% overload capacity is needed, use the larger
fuse alternative.
Fuses, losses and frame sizes
Type
Fuses
1)
Heat dissipation
Air flow
Frame
size
ACS355
gG
UL Class T
(600 V)
Main circuit Control circuit
x = E/U
Rated /1N and
/2N
Max
A
A
W
W
m3/h
ft3/min
1-phase UN = 200…240 V
01x-02A4-2
10
10
25
22.7
-
-
R0
01x-04A7-2
16
20
46
26.4
24
14
R1
01x-06A7-2
16/20
2)
25
71
26.4
24
14
R1
01x-07A5-2
20/25
2)
30
73
27.5
21
12
R2
01x-09A8-2
25/35
2)
35
96
27.5
21
12
R2
3-phase UN = 200…240 V
03x-02A4-2
10
10
19
22.7
-
-
R0
03x-03A5-2
10
10
31
22.7
-
-
R0
03x-04A7-2
10
15
38
26.4
24
14
R1
03x-06A7-2
16
15
60
26.4
24
14
R1
03x-07A5-2
16
15
62
26.4
21
12
R1
03x-09A8-2
16
20
83
27.5
21
12
R2
03x-13A3-2
25
30
112
27.5
52
31
R2
03x-17A6-2
25
35
152
27.5
52
31
R2
03x-24A4- 2
63
60
250
35.4
71
42
R3
03x-31A0-2
80
80
270
57.8
96
57
R4
03x-46A2-2
100
100
430
57.8
96
57
R4
3-phase UN = 380…480 V
03x-01A2-4
10
10
11
24.4
-
-
R0
03x-01A9-4
10
10
16
24.4
-
-
R0
03x-02A4-4
10
10
21
28.7
13
8
R1
03x-03A3-4
10
10
31
28.7
13
8
R1
03x-04A1-4
16
15
40
28.7
13
8
R1
03x-05A6-4
16
15
61
28.7
19
11
R1
03x-07A3-4
16
20
74
32.7
24
14
R1
03x-08A8-4
20
25
94
32.7
24
14
R1
03x-12A5-4
25
30
130
31.2
52
31
R3
03x-15A6-4
35
35
173
31.2
52
31
R3
03x-23A1-4
50
50
266
35.4
71
42
R3
03x-31A0-4
80
80
350
57.8
96
57
R4
03x-38A0-4
100
100
440
57.8
96
57
R4
03x-44A0-4
100
100
530
57.8
96
57
R4
00353783.xls J