Parameters 93
Parameter listing
No.
Name/Value
Description
Default
FbEq 16
01
Basic signals for monitoring the drive.
All parameters in this group are read-only unless
otherwise noted.
Note:
Values of these actual signals are filtered with
the filter time defined in group
. The selection lists for parameters in other
groups mean the raw value of the actual signal
instead. For example, if a selection is “Output
frequency” it does not point to the value of parameter
but to the raw value.
Estimated motor speed. A filter time constant for this
signal can be defined by parameter
.
-
-30000.00… 30000.00
rpm
Estimated motor speed.
See par.
Actual speed in percent of the motor synchronous
speed. The filter time constant can be adjusted by
parameter
-
-1000.00… 1000.00%
Motor speed.
See par.
Estimated drive output frequency in Hz. A filter time
constant for this signal can be defined by parameter
46.12
.
-
-598.00…598.00 Hz
Estimated output frequency.
See par.
Measured (absolute) motor current in A.
-
0.00…30000.00
Motor current.
See par.
Motor current (drive output current) in percent of the
nominal motor current.
-
0.0…1000.0%
Motor current.
1=1%
Motor current (drive output current) in percent of the
nominal drive current.
-
0.0…1000.0%
Motor current.
1=1%
Motor torque in percent of the nominal motor torque.
A filter time constant for this signal can be defined by
parameter
.
-
-1600.0…1600.0%
Motor torque.
See par.
Measured intermediate circuit DC Link voltage.
-
0.00…2000.00 V
DC link voltage.
10 = 1 V
Calculated motor voltage in V AC.
-
0…2000 V
Motor voltage.
1 = 1 V
Содержание ACS280
Страница 1: ... ABB MACHINERY DRIVES ACS280 coldplate drives Firmware manual ...
Страница 4: ......
Страница 10: ...10 ...
Страница 16: ...16 Control panel ...
Страница 20: ...20 Start up ID run and use ...
Страница 24: ...24 Default control connection ...
Страница 88: ...88 Program features ...
Страница 298: ...298 Parameters ...