Parameters 277
Bits 8…9 select which comparison(s) are made:
• Bit 8 = 1 (Approved checksum A):
is compared to
, and/or
• Bit 9 = 1 (Approved checksum A): if
.
Bits 12…13 select approved (reference) checksum
parameter(s) into which the actual checksum(s) from
parameter(s) are copied:
• Bit 12 = 1 (Set approved checksum A): Value of
is copied into
and/or
• Bit 13 = 1 (Set approved checksum B): Value of
copied into
.
0b0000
0b0000...0b1111
Checksum control word.
1 = 1
Displays the actual parameter configuration
checksum A. The checksum A is generated and
updated whenever an action is selected in
bit 8 = 1 (Approved checksum A)
The set of parameters for checksum A calculation
does not include fieldbus settings parameters.
The parameters included in the checksum A
calculation are user editable parameters in parameter
groups 10, 15, 19, 20, 21, 22, 23, 24, 25, 28, 30, 31, 32, 35,
36, 37, 40, 41, 45, 46, 71, 95, 96, 97, 98, and 99.
See also section
Parameter checksum calculation
(page
).
0x0000
0x0000...0xffff
Actual checksum A.
1 = 1
No.
Name/Value
Description
Default
FbEq 16
Bit
Name
Information
0...7
Reserved
8
Approved checksum A
1 = Enabled: Checksum A (
) is observed. 0 =
Disabled.
9
Approved checksum B
1 = Enabled: Checksum B (
) is observed. 0 =
Disabled.
10...11
Reserved
12
Set approved checksum
A
. 0 = Done (copy
has
been made).
13
Set approved checksum
B
into
. 0 = Done (copy
has
been made).
14...15 Reserved
Содержание ACS280
Страница 1: ... ABB MACHINERY DRIVES ACS280 coldplate drives Firmware manual ...
Страница 4: ......
Страница 10: ...10 ...
Страница 16: ...16 Control panel ...
Страница 20: ...20 Start up ID run and use ...
Страница 24: ...24 Default control connection ...
Страница 88: ...88 Program features ...
Страница 298: ...298 Parameters ...