Parameters 227
Freq in scaled
11.39
Freq in 1 scaled value
10
AI1 percent
AI2 percent
12
Control panel (ref
saved)
Panel reference (
, see page
)
saved by the control system for the location where
the control returns is used as the reference.
13
Control panel (ref
copied)
Panel reference (
, see page
)
for the previous control location is used as the
reference when the control location changes if the
references for the two locations are of the same type
(eg frequency/speed/torque/PID); otherwise, the
actual signal is used as the new reference.
14
EFB ref1
19
EFB ref2
20
Setpoint data storage
24
-
Selects the second source of process setpoint. The
second source is used only if the setpoint function
requires two inputs.
For the selections, see parameter
Selects a function between the setpoint sources
selected by parameters
and
In1 Source
1.
0
In1+In2
Sum of sources 1 and 2.
1
In1-In2
Source 2 subtracted from source 1.
2
In1*In2
Source 1 multiplied by source 2.
3
In1/In2
Source 1 divided by source 2.
4
MIN(In1,In2)
Smaller of the two sources.
5
MAX(In1,In2)
Greater of the two sources.
6
AVE(In1,In2)
Average of the two sources.
7
sqrt(In1)
Square root of source 1.
8
sqrt(In1-In2)
Square root of (source 1 - source 2).
9
No.
Name/Value
Description
Default
FbEq 16
Ext1 -> Ext2
t
Reference
Ext1 reference
Ext2 reference
Active reference
Inactive reference
Ext1 -> Ext2
Ext1 reference
Ext2 reference
Active reference
t
Inactive reference
Reference
Содержание ACS280
Страница 1: ... ABB MACHINERY DRIVES ACS280 coldplate drives Firmware manual ...
Страница 4: ......
Страница 10: ...10 ...
Страница 16: ...16 Control panel ...
Страница 20: ...20 Start up ID run and use ...
Страница 24: ...24 Default control connection ...
Страница 88: ...88 Program features ...
Страница 298: ...298 Parameters ...