Parameters 141
Standstill
The standstill modes can be used if the motor cannot
be turned (for example, when load is connected).
Notes:
•
For SynRM, PMaSynRM, and internal permanent
magnet motors, autophasing time is usually less
than 1 second.
• For surface permanent magnet motors,
autophasing time is usually from 1 to 2 seconds.
Also, pulsating torque up to the nominal torque is
produced in this type of motor and therefore loud
noise may occur.
4
Turning 2
This mode is like Turning autophasing mode with the
difference that at the end of turning autophasing
routine, rotor turns by 180 electrical degrees.
5
Selects the source for triggering pre-heating for the
motor. The status of the pre-heating is shown as bit 2
of
.
Notes:
• The heating function requires that STO is not
triggered.
• The heating function requires that the drive is not
faulted.
• Pre-heating uses DC hold to produce current.
Off
0. Pre-heating is always deactivated.
0
On
1. Pre-heating is always activated when the drive is
stopped.
1
DI1
Digital input DI1 (
, bit 0).
2
DI2
Digital input DI2 (
, bit 1).
3
DI3
Digital input DI3 (
, bit 2).
4
DI4
Digital input DI4 (
, bit 3).
5
Supervision 1
). 8
Supervision 2
(see page
).
9
Supervision 3
(see page
).
10
-
Time delay before pre-heating starts after the drive is
stopped.
60 s
10...3000 s
Pre-heating time delay.
1 = 1 s
Defines the DC current used to heat the motor. The
value is in percent of the nominal motor current.
0.0%
0.0…30.0%
Pre-heating current.
1 = 1%
No.
Name/Value
Description
Default
FbEq 16
Содержание ACS280
Страница 1: ... ABB MACHINERY DRIVES ACS280 coldplate drives Firmware manual ...
Страница 4: ......
Страница 10: ...10 ...
Страница 16: ...16 Control panel ...
Страница 20: ...20 Start up ID run and use ...
Страница 24: ...24 Default control connection ...
Страница 88: ...88 Program features ...
Страница 298: ...298 Parameters ...