Parameters 279
Reset end user texts
Restores all end user texts to default values, including the
drive name, contact info, customized fault and warning
texts and currency unit.
If the value of parameter
is set to
User Text,
then
the PID unit is also reset. If parameter
has some
other value, the PID unit cannot be reset.
1024
Reset motor data
Restores all motor nominal values and motor ID run
results to default values.
2
All to factory defaults
Restores settings and all editable parameters back to
initial factory values, except
the differentiated defaults implemented by parameter
95.20.
34560
Saves the valid parameter values to the permanent
memory on the drive control board to ensure that
operation can continue after cycling the power. Save the
parameters with this parameter
• to store values sent from the fieldbus
• when using ex24 V DC power supply to the
control unit: to save parameter changes before you
power down the control unit. The supply has a very
short hold-up time when powered off.
Note:
A new parameter value is saved automatically
when changed from the PC tool or control panel but not
when altered through a fieldbus adapter connection.
Done
Save completed.
0
Save
Save in progress.
1
Changing the value of this parameter to 1 reboots the
control unit (without requiring a power off/on cycle of the
complete drive module).
The value reverts to 0 automatically.
0
0
No action
1 = 1
1
Reboot the control unit.
Shows the status of the user parameter sets.
This parameter is read-only.
See also section
(page
).
-
n/a
No user parameter sets have been saved.
0
Loading
A user set is being loaded.
1
Saving
A user set is being saved.
2
Faulted
Invalid or empty parameter set.
3
User1 IO active
User set 1 has been selected by parameters
4
User2 IO active
User set 2 has been selected by parameters
5
User3 IO active
User set 3 has been selected by parameters
6
User4 IO active
User set 4 has been selected by parameters
7
User1 backup
User set 1 has been saved or loaded.
20
User2 backup
User set 2 has been saved or loaded.
21
No.
Name/Value
Description
Default
FbEq 16