Fault tracing
287
Warning messages generated by the control panel
WARNING
CAUSE
WHAT TO DO
DOWNLOADING
FAILED
Download function of panel has failed. No data
has been copied from panel to drive.
Make sure panel is in local mode.
Retry (there might be interference on link).
Contact ABB representative.
DRIVE IS
RUNNING
DOWNLOADING
NOT POSSIBLE
Downloading is not possible while motor is
running.
Stop motor. Perform downloading.
NO
COMMUNICATION
(X)
Cabling problem or hardware malfunction on
Panel Link
Check Panel Link connections.
Press RESET key. Panel reset may take up to
half a minute, please wait.
(4) = Panel type not compatible with drive
application program version
Check panel type and drive application
program version. Panel type is printed on
panel cover. Application program version is
stored in parameter
.
NO FREE ID
NUMBERS ID
NUMBER
SETTING NOT
POSSIBLE
Panel Link already includes 31 stations.
Disconnect another station from link to free ID
number.
NOT UPLOADED
DOWNLOADING
NOT POSSIBLE
No upload function has been performed.
Perform upload function before downloading.
See chapter
.
UPLOADING
FAILED
Upload function of panel has failed. No data
has been copied from drive to panel.
Retry (there might be interference on link).
Contact ABB representative.
WRITE ACCESS
DENIED
PARAMETER
SETTING NOT
POSSIBLE
Certain parameters do not allow changes while
motor is running. If tried, no change is
accepted, and warning is displayed.
Stop motor, then change parameter value.
Parameter lock is on.
Open parameter lock (see parameter
).
Содержание ACS 800 Series
Страница 1: ...ACS800 Firmware Manual Crane Control Program N697 ...
Страница 4: ......
Страница 26: ...Start up and control through the I O interface 26 ...
Страница 36: ...Quick start up guide 36 ...
Страница 52: ...Control panel 52 ...
Страница 105: ...Program features 105 Figure Control diagram for Shaft synchronisation executed in 20 ms ...
Страница 126: ...Program features 126 The figures below show speed limits according to different load conditions ...
Страница 128: ...Program features 128 ...
Страница 150: ...Application macros control location EXT1 EXT2 150 ...
Страница 228: ...Actual signals and parameters 228 ...
Страница 299: ...Adaptive Programming examples for crane control 299 ...
Страница 305: ...Adaptive Programming examples for crane control 305 ...
Страница 312: ...Adaptive Programming examples for crane control 312 The following figures show the previous example enlarged ...
Страница 314: ...Adaptive Programming examples for crane control 314 The following figures show the previous example enlarged ...
Страница 318: ...Analogue Extension Module 318 ...
Страница 332: ...Additional data actual signals and parameters 332 ...
Страница 333: ...DriveWindow 333 DriveWindow DriveWindow connected to the ACS800 RMIO RDCO board and channel CH3 ...
Страница 334: ...DriveWindow 334 ...
Страница 335: ...Control block diagrams 335 Control block diagrams ...
Страница 336: ...Control block diagrams 336 ...
Страница 337: ...Control block diagrams 337 ...
Страница 338: ...Control block diagrams 338 ...
Страница 340: ...www abb com drives www abb com drivespartners Contact us 3AFE68775230 Rev E EN 2012 09 25 ...