Fieldbus control
277
03.37 FCW WITH POS
04.01 FAULTED INT INFO
The FAULTED INT INFO Word includes information on the location of faults PPCC
LINK, OVERCURRENT, EARTH FAULT, SHORT CIRCUIT, ACS800 TEMP,
TEMP DIF and POWERF INV (see
and chapter
).
Bit
Name
Description
0 … 2
Reserved
3
START
Follower Start command from Master
4
POS BIT 0
Position multiplying factor bit 0. For more details see
section
Control location EXT1/EXT2 supervision mismatch
5
POS BIT 1
Position multiplying factor bit 1. For more details see
section
Control location EXT1/EXT2 supervision mismatch
6
POS BIT 2
Position multiplying factor bit 2. For more details see
section
Control location EXT1/EXT2 supervision mismatch
7
RESET
Follower drive Reset command from Master
8
POS BIT 3
Position multiplying factor bit 3. For more details see
section
Control location EXT1/EXT2 supervision mismatch
9
POS BIT 4
Position multiplying factor bit 4. For more details see
section
Control location EXT1/EXT2 supervision mismatch
10
POS BIT 5
Position multiplying factor bit 5. For more details see
section
Control location EXT1/EXT2 supervision mismatch
11 … 15
Reserved
Bit
Name
Description
0
INT 1 FLT
INT 1 board fault
1
INT 2 FLT
INT 2 board fault
2
INT 3 FLT
INT 3 board fault
3
INT 4 FLT
INT 4 board fault
4
INT 5 FLT
INT 5 board fault
5
INT 6 FLT
INT 6 board fault
6
INT 7 FLT
INT 7 board fault
7
INT 8 FLT
INT 8 board fault
8
INT 9 FLT
INT 9 board fault
9
INT 10 FLT
INT 10 board fault
10
INT 11 FLT
INT 11 board fault
11
INT 12 FLT
INT 12 board fault
12 … 14
Reserved
Содержание ACS 800 Series
Страница 1: ...ACS800 Firmware Manual Crane Control Program N697 ...
Страница 4: ......
Страница 26: ...Start up and control through the I O interface 26 ...
Страница 36: ...Quick start up guide 36 ...
Страница 52: ...Control panel 52 ...
Страница 105: ...Program features 105 Figure Control diagram for Shaft synchronisation executed in 20 ms ...
Страница 126: ...Program features 126 The figures below show speed limits according to different load conditions ...
Страница 128: ...Program features 128 ...
Страница 150: ...Application macros control location EXT1 EXT2 150 ...
Страница 228: ...Actual signals and parameters 228 ...
Страница 299: ...Adaptive Programming examples for crane control 299 ...
Страница 305: ...Adaptive Programming examples for crane control 305 ...
Страница 312: ...Adaptive Programming examples for crane control 312 The following figures show the previous example enlarged ...
Страница 314: ...Adaptive Programming examples for crane control 314 The following figures show the previous example enlarged ...
Страница 318: ...Analogue Extension Module 318 ...
Страница 332: ...Additional data actual signals and parameters 332 ...
Страница 333: ...DriveWindow 333 DriveWindow DriveWindow connected to the ACS800 RMIO RDCO board and channel CH3 ...
Страница 334: ...DriveWindow 334 ...
Страница 335: ...Control block diagrams 335 Control block diagrams ...
Страница 336: ...Control block diagrams 336 ...
Страница 337: ...Control block diagrams 337 ...
Страница 338: ...Control block diagrams 338 ...
Страница 340: ...www abb com drives www abb com drivespartners Contact us 3AFE68775230 Rev E EN 2012 09 25 ...