Actual signals and parameters
214
85.09
CONSTANT9
Sets a constant for the Adaptive Program.
-8388608 to 8388607
Integer value
1 = 1
85.10
CONSTANT10
Sets a constant for the Adaptive Program.
-8388608 to 8388607
Integer value
1 = 1
85.11
STRING1
Stores a message to be used in the Adaptive Program (EVENT block).
MESSAGE1
Message
-
85.12
STRING2
Stores a message to be used in the Adaptive Program (EVENT block).
MESSAGE2
Message
-
85.13
STRING3
Stores a message to be used in the Adaptive Program (EVENT block).
MESSAGE3
Message
-
85.14
STRING4
Stores a message to be used in the Adaptive Program (EVENT block).
MESSAGE4
Message
-
85.15
STRING5
Stores a message to be used in the Adaptive Program (EVENT block).
MESSAGE5
Message
-
90 D SET REC ADDR
- Addresses into which the received fieldbus data sets are written.
- Numbers of the main and auxiliary data sets.
The parameters are visible only when a fieldbus communication is activated
with parameter
. For more information, see chapter
90.01
AUX1 DS REF3
Selects the address into which the value of fieldbus reference REF3 is written.
0 … 8999
Parameter index
90.02
AUX1 DS REF4
Selects the address into which the value of fieldbus reference REF4 is written.
0 … 8999
Parameter index
90.03
AUX1 DS REF5
Selects the address into which the value of fieldbus reference REF5 is written.
0 … 8999
Parameter index
90.04
AUX2 DS REF6
Selects the address into which the value of fieldbus reference REF6 is written.
0 … 8999
Parameter index
90.05
AUX2 DS REF7
Selects the address into which the value of fieldbus reference REF7 is written.
0 … 8999
Parameter index
90.06
AUX2 DS REF8
Selects the address into which the value of fieldbus reference REF8 is written.
0 … 8999
Parameter index
90.07
START DS REC
Defines the starting data set from which the drive reads the Control Word,
Reference REF1 and Reference REF2.
1
Data set number 1 is the starting address. Can be used for standard drives.
1
10
Data set number 10 is the starting address. Can be used for multidrives.
2
92 D SET TR ADDR
Main and Auxiliary Data Sets which the drive sends to the fieldbus master
station.
The parameters are visible only when a fieldbus communication is activated
with parameter
. For more information, see chapter
92.01
MAIN DS STATUS
WORD
Stores the address from which the Main Status Word is read from. Fixed value,
not visible.
302 (fixed)
Parameter index
92.02
MAIN DS ACT1
Selects the address from which the Actual signal 1 is read to the Main Data
Set.
0 … 9999
Parameter index
Index
Name/Selection
Description
FbEq
Содержание ACS 800 Series
Страница 1: ...ACS800 Firmware Manual Crane Control Program N697 ...
Страница 4: ......
Страница 26: ...Start up and control through the I O interface 26 ...
Страница 36: ...Quick start up guide 36 ...
Страница 52: ...Control panel 52 ...
Страница 105: ...Program features 105 Figure Control diagram for Shaft synchronisation executed in 20 ms ...
Страница 126: ...Program features 126 The figures below show speed limits according to different load conditions ...
Страница 128: ...Program features 128 ...
Страница 150: ...Application macros control location EXT1 EXT2 150 ...
Страница 228: ...Actual signals and parameters 228 ...
Страница 299: ...Adaptive Programming examples for crane control 299 ...
Страница 305: ...Adaptive Programming examples for crane control 305 ...
Страница 312: ...Adaptive Programming examples for crane control 312 The following figures show the previous example enlarged ...
Страница 314: ...Adaptive Programming examples for crane control 314 The following figures show the previous example enlarged ...
Страница 318: ...Analogue Extension Module 318 ...
Страница 332: ...Additional data actual signals and parameters 332 ...
Страница 333: ...DriveWindow 333 DriveWindow DriveWindow connected to the ACS800 RMIO RDCO board and channel CH3 ...
Страница 334: ...DriveWindow 334 ...
Страница 335: ...Control block diagrams 335 Control block diagrams ...
Страница 336: ...Control block diagrams 336 ...
Страница 337: ...Control block diagrams 337 ...
Страница 338: ...Control block diagrams 338 ...
Страница 340: ...www abb com drives www abb com drivespartners Contact us 3AFE68775230 Rev E EN 2012 09 25 ...