22
ACQ550-CC Packaged Drive with Bypass
Technical Data
Power Connection Terminals
The following tables show maximum wire size and required tightening torque for
incoming power, motor, and grounding terminals.
208…240 Volt, Terminals
208…240 Volt, Power Connection Terminal Data
208/240 Volt
Base
Drive
Frame
Size
Power Wiring Size
HP
Type Code
Circuit
Breaker
Overload
Relay
Ground Lugs
1
ACQ550-CC-04A6-2
R1
#10
62 in-lbs
#10
22 in-lbs
#2
15 in-lbs
(#14 - #12)
40 in-lbs
(#10 - #6)
50 in-lbs
(#4 - #2)
1.5
ACQ550-CC-06A6-2
R1
2
ACQ550-CC-07A5-2
R1
3
ACQ550-CC-012A-2
R1
5
ACQ550-CC-017A-2
R1
7.5
ACQ550-CC-024A-2
R2
#6
62 in-lbs
10
ACQ550-CC-031A-2
R2
#8
22 in-lbs
15
ACQ550-CC-046A-2
R3
#3
62 in-lbs
#3
40 in-lbs
20
ACQ550-CC-059A-2
R3
25
ACQ550-CC-075A-2
R4
#1
62 in-lbs
#1
80 in-lbs
#6-2/0
88 in-lbs
30
ACQ550-CC-088A-2
R4
#2/0
195 in-lbs
40
ACQ550-CC-114A-2
R4
50
ACQ550-CC-143A-2
R6
300 MCM
274 in-lbs
250 MCM
160 in-lbs
#2/0
275 in-lbs
(#6 - #2)
375 in-lbs
(#1 - #2/0)
60
ACQ550-CC-178A-2
R6
75
ACQ550-CC-221A-2
R6
2 x 250 MCM
275 in-lbs
500 MCM
247 in-lbs
350 MCM
100 in-lbs
100
ACQ550-CC-248A-2
R6