270 Parameters
90.02
EMUL MODE SEL
Enables encoder emulation and selects the position
value and the TTL output used in the emulation
process.
In encoder emulation, a calculated position
difference is transformed to a corresponding number
of TTL pulses to be transmitted via the TTL output.
The position difference is the difference between the
latest and the previous position values.
The position value used in emulation can be either a
position determined by the drive software or a
position measured by an encoder. If the drive
software position is used, the source for the used
position is selected by parameter
EMUL POS
REF. Because the software causes a delay, it is
recommended that the actual position is always
taken from an encoder. Drive software is
recommended to be used only with position
reference emulation.
Encoder emulation can be used to increase or
decrease the pulse number when TTL encoder data
is transmitted via the TTL output, for example, to
another drive. If the pulse number requires no
alternation, use encoder echo for data
transformation. See parameter
TTL ECHO
SEL.
Note:
If encoder emulation and echo are enabled for
the same FEN-xx TTL output, the emulation
overrides the echo.
If an encoder input is selected as the emulation
source, the corresponding selection must be
activated with parameter
ENCODER SEL.
The TTL encoder pulse number used in emulation
must be defined by parameter
EMUL PULSE
.
Disabled /
Disabled
Emulation disabled.
0
FEN-01 SWref
Module type: FEN-01 TTL Encoder interface Module.
Emulation: Drive software position (source selected
by par.
EMUL POS REF) is emulated to FEN-
01 TTL output.
1
FEN-01 TTL+
Module type: FEN-01 TTL Encoder interface Module.
Emulation: FEN-01 TTL encoder input (X32) position
is emulated to FEN-01 TTL output.
2
FEN-01 TTL
Module type: FEN-01 TTL Encoder interface Module.
Emulation: FEN-01 TTL encoder input (X31) position
is emulated to FEN-01 TTL output.
3
No.
Bit/Name/Value/
Range
Description
Def/Type
FbEq
(16b/32b)
Содержание ACL30
Страница 1: ...ABB high performance elevator drives User s manual ACL30 elevator drive ...
Страница 4: ......
Страница 20: ...20 Safety instructions ...
Страница 34: ...34 Operation principle and hardware description ...
Страница 42: ...42 Planning the cabinet installation ...
Страница 60: ...60 Planning the electrical installation ...
Страница 126: ...126 Using the control panel ...
Страница 318: ...318 Maintenance ...
Страница 334: ...334 The Safe torque off function ...
Страница 338: ...338 Mains chokes ...
Страница 342: ...342 EMC filters ...
Страница 348: ...Dimension drawings 348 Frame size B D1 D2 W H1 H2 ...
Страница 349: ...Dimension drawings 349 ...
Страница 350: ...Dimension drawings 350 Frame size C D1 D2 H2 H1 W ...
Страница 351: ...Dimension drawings 351 ...
Страница 352: ...Dimension drawings 352 Frame size D ...
Страница 354: ...354 Dimension drawings EMC filters JFI 0x ...
Страница 356: ...356 Dimension drawings Brake resistors JBR xx ...
Страница 358: ...358 Dimension drawings ...
Страница 360: ...Contact us www abb com drives www abb com drivespartners 3AXD50000036355 Rev B EN EFFECTIVE 2016 11 21 ...