Program features 135
Evacuation mode
The Evacuation mode is used in the elevator car rescue operation in case power
supply fails. For a detailed description of the operation of this mode and rescue
operation in general, see section
on page
.
Inspection mode
The Inspection mode is used for maintenance operations. You can enable it with
parameter
INSPECTION MODE. In this mode, the elevator can be operated
with parameters
INSPECTION UP and
INSPECTION DOWN, as shown
in the table below. The standard start up/down commands (see section
) are disabled.
When the elevator operates in the Inspection mode, the drive uses parameter
INSPECTION SPEED as the speed reference and parameters
INSPECT
INSPECT MODE DEC for acceleration and deceleration,
respectively.
Besides the Inspection mode, it is also possible to conduct maintenance operations
while the elevator is running at the inspection speed in the normal travel mode. In this
case, the inspection speed is selected based on the combined status of parameters
SPEED REF SEL1,
SPEED REF SEL2,
SPEED REF SEL3 and
SPEED REF SEL4, and the elevator travel is started with the standard start
up/down commands. The Inspection mode as well as the Inspection mode up/down
commands are disabled.
Settings
Par.
Command
0
0
Stop
1
0
Inspection mode up
0
1
Inspection mode down
1
1
Stop
Parameters
Additional information
INSPECTION MODE
Selects the source for enabling/disabling the inspection mode.
INSPECTION UP
Selects the source for starting the elevator in the upward direction in the
inspection mode.
INSPECTION DN
Defines the source for starting the elevator in the downward direction in
the inspection mode.
INSPECT MODE ACC
Defines the acceleration used in the inspection mode.
INSPECT MODE DEC
Defines the deceleration used in the inspection mode.
INSPECTION SPEED
Defines the speed reference used in the inspection mode. Can also be
used in the normal travel mode if the inspection mode is not in use.
Содержание ACL30
Страница 1: ...ABB high performance elevator drives User s manual ACL30 elevator drive ...
Страница 4: ......
Страница 20: ...20 Safety instructions ...
Страница 34: ...34 Operation principle and hardware description ...
Страница 42: ...42 Planning the cabinet installation ...
Страница 60: ...60 Planning the electrical installation ...
Страница 126: ...126 Using the control panel ...
Страница 318: ...318 Maintenance ...
Страница 334: ...334 The Safe torque off function ...
Страница 338: ...338 Mains chokes ...
Страница 342: ...342 EMC filters ...
Страница 348: ...Dimension drawings 348 Frame size B D1 D2 W H1 H2 ...
Страница 349: ...Dimension drawings 349 ...
Страница 350: ...Dimension drawings 350 Frame size C D1 D2 H2 H1 W ...
Страница 351: ...Dimension drawings 351 ...
Страница 352: ...Dimension drawings 352 Frame size D ...
Страница 354: ...354 Dimension drawings EMC filters JFI 0x ...
Страница 356: ...356 Dimension drawings Brake resistors JBR xx ...
Страница 358: ...358 Dimension drawings ...
Страница 360: ...Contact us www abb com drives www abb com drivespartners 3AXD50000036355 Rev B EN EFFECTIVE 2016 11 21 ...