80.14
MEDIUM SPEED
Defines the speed reference to be used in the normal
travel mode when the bit combination of parameters
,
and
is 010. This is an additional
speed reference which can be defined to be used
instead of the nominal speed based on the floor
distance.
0.50 m/s /
0.00…25.00 m/s
Medium speed reference.
100 = 1 m/s
80.15
INSPECTION
SPEED
Defines the speed reference to be used when the
inspection mode is enabled with parameter
INSPECTION MODE. If the inspection mode is not in
use, this speed reference can also be defined to be
used in the normal travel mode when the bit
combination of parameters
and
101.
0.25 m/s /
0.00…25.00 m/s
Inspection speed reference.
100 = 1 m/s
80.16
EVACUATION
SPEED
Defines the speed reference to be used when the
evacuation mode is enabled with parameter
EVACUATION MODE.
0.10 m/s /
0.00…25.00 m/s
Evacuation speed reference.
100 = 1 m/s
80.17
SPEED2
Defines the speed reference to be used in the normal
travel mode when the bit combination of parameters
,
and
is 001. This is an additional
speed reference which can be defined to be used
instead of the nominal speed based on the floor
distance.
0.40 m/s /
0.00…25.00 m/s
Speed2.
100 = 1 m/s
80.18
SPEED3
Defines the speed reference to be used in the normal
travel mode when the bit combination of parameters
,
and
is 001. This is an additional
speed reference which can be defined to be used
instead of the nominal speed based on the floor
distance.
0.60 m/s /
0.00…25.00 m/s
Speed3.
100 = 1 m/s
80.19
OFF DLY SPD LIM
Defines the lift speed limit for activating the extended
off-delay time periods defined with parameters
. The delay periods are used only when the
lift speed
is lower than this limit.
0.00 m/s /
0.00…25.00 m/s
Off-delay speed limit.
100 = 1 m/s
No.
Bit/Name/Value/
Range
Description
Def/Type
FbEq
(16b/32b)
Содержание ACL30
Страница 1: ...ABB high performance elevator drives User s manual ACL30 elevator drive ...
Страница 4: ......
Страница 20: ...20 Safety instructions ...
Страница 34: ...34 Operation principle and hardware description ...
Страница 42: ...42 Planning the cabinet installation ...
Страница 60: ...60 Planning the electrical installation ...
Страница 126: ...126 Using the control panel ...
Страница 318: ...318 Maintenance ...
Страница 334: ...334 The Safe torque off function ...
Страница 338: ...338 Mains chokes ...
Страница 342: ...342 EMC filters ...
Страница 348: ...Dimension drawings 348 Frame size B D1 D2 W H1 H2 ...
Страница 349: ...Dimension drawings 349 ...
Страница 350: ...Dimension drawings 350 Frame size C D1 D2 H2 H1 W ...
Страница 351: ...Dimension drawings 351 ...
Страница 352: ...Dimension drawings 352 Frame size D ...
Страница 354: ...354 Dimension drawings EMC filters JFI 0x ...
Страница 356: ...356 Dimension drawings Brake resistors JBR xx ...
Страница 358: ...358 Dimension drawings ...
Страница 360: ...Contact us www abb com drives www abb com drivespartners 3AXD50000036355 Rev B EN EFFECTIVE 2016 11 21 ...