Technical Data

Product Manual  2CQA 100 001 B0001

  2018-09-28

9

4  Technical Data

4.1

Technical Data

Description

Value

Operating Voltage

120 V AC, 60 Hz

Operating Voltage Range

103 VAC to 121 VAC

Connection

L-wire and N-wire Required

Binary Input Voltage

120 VAC Nominal

Maximum Power Consumption

< 1 W

Standby*

 P

ower Consumption

< 300 mW

Transmission Protocol

free@home, 2.400 - 2.483 GHz, meshed

Transmission Power

< 15 dBm

Protection Type

IP 20

Ambient Temperature Range

23° F to 113° F (-5° C to 45° C)

Storage Temperature Range

-40° F to 140° F (-40° C to 60° C)

*

If output is OFF and no active wireless communication

4.2

Load Table

Load Type

Value

Incandescent or Halogen Lamp

15 A (1800 W)

Magnetic Low-Voltage Transformer (MLV)

8 A (960 W)

Electronic Low-Voltage Transformer (ELV)

15 A (1800 W)

Fan, Maximum 1 Fan Allowed

400 W

Fluorescent Lamps, without Compensation or Ballast

12 A (1440 W)

LED Lamps, Maximum 20 Lamps Allowed

180 W

Содержание ABB-free@home LS-1.1

Страница 1: ...2CQA 100 001 B0001 2018 09 28 Product Manual ABB free home LS 1 1 Light Switch ...

Страница 2: ...le of co ntent s 1 The Device 3 1 1 Basic Operation 3 1 2 Advanced Operation 3 2 Adding the Light Switch 4 3 Configuring the Light Switch 7 3 1 Light Switch Settings 7 3 2 LED Settings 8 4 Technical Data 9 4 1 Technical Data 9 4 2 Load Table 9 5 Resetting the Device 10 ...

Страница 3: ... way installation Note A neutral wire is required 1 1 Basic Operation To turn ON Press the top of the rocker switch To turn OFF Press the bottom of the rocker switch LED Indicator The LED is lit when the connected lighting is ON 1 2 Advanced Operation The Light Switch can be configured to perform many convenient features for the user See Configuring the Light Switch for instructions on the feature...

Страница 4: ...to the free home network If the Light Switch has been assigned to a different SysAP it will need to be reset Please see here for instructions STEP 2 Open configuration and search for the Light Switch Ensure that the SysAP is in Access Point mode by pressing the button on the SysAP The indicator light will turn solid blue Connect to the SysAP by selecting it from the list in your wireless network O...

Страница 5: ...t Switch will be found automatically and will be inserted into the configuration software Please wait until the Light Switch configuration is read This may take up to 10 minutes STEP 3 Add the Light to the floor plan A Go To Devices B Click on Light or whatever new element was wired to the Light Switch C Drag the light bulb symbol or other element into the floor plan D Choose the device from the l...

Страница 6: ... floor plan corresponding to the Rocker Step 5 Connect the Light Switch to the Light A Click on Rocker in the floor plan Select Rocker from the drop down menu that pops up B In the menu on the right hand side of the screen click on the button that says Rocker C Click on the Light or other element in the floor plan This creates a link between the two devices A link between a Rocker and Socket Outle...

Страница 7: ...ptions Image Autonomous switch off time duration s This setting is only used in combination with a motion detector Light Switch will automatically switch OFF after time has elapsed 30 to 1800 Behavior on malfunction Defines the reaction in case of power failure This setting is locked at No reaction STEP 2 Rocker Settings After clicking on the rocker symbol select Rocker Binary Input is only used w...

Страница 8: ...rightness night User can adjust brightness of LED n a LED switch on brightness day User can adjust brightness of LED n a LED mode Defines the reaction of the LED on the rocker Orientation light LED is always ON to find Light Switch at night Status indication LED shows status of light i e LED is ON when switch is ON and OFF when switch is OFF ...

Страница 9: ...ocol free home 2 400 2 483 GHz meshed Transmission Power 15 dBm Protection Type IP 20 Ambient Temperature Range 23 F to 113 F 5 C to 45 C Storage Temperature Range 40 F to 140 F 40 C to 60 C If output is OFF and no active wireless communication 4 2 Load Table Load Type Value Incandescent or Halogen Lamp 15 A 1800 W Magnetic Low Voltage Transformer MLV 8 A 960 W Electronic Low Voltage Transformer E...

Страница 10: ...ld the bottom of the rocker for at least 20 seconds B The bottom LED light will start flashing after 10 seconds C After another 5 seconds the LED will start flashing rapidly After another 5 seconds the LED light will turn off D Release the bottom of the rocker within the next 10 seconds E Then press the bottom of the rocker The lower LED light will stay on Press the bottom of the rocker again The ...

Страница 11: ...eserve the right at all times to make technical changes as well as changes to the contents of this document without prior notice The detailed specifications agreed upon apply for orders ABB accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations contained therein The document and its contents or extrac...

Отзывы: