Operation Manual / A130-H.. - A140-H..
3 Removing and Installing / 3.2 Removing the turbocharger
© Copyright 2021 ABB. All rights reserved.
HZTL4030_EN
Rev.G
July 2021
3.2.1
Fastening of the turbocharger
WARNING
Risk of scalding from hot water
If the water connections are removed immediately after taking the tur-
bocharger out of operation, the hot cooling water that flows out can cause
scalding if it comes into contact with the skin.
u
Allow turbocharger to cool down before removing the water pipes.
u
Wear safety gloves to protect against thermal hazards.
Wear safety gloves to protect against mechanical hazards.
CAUTION
Freezing of the cooling water in the bearing casing
Serious damage to property can be the consequence if the cooling water
freezes in the pipes and in the bearing casing.
u
For transport and storage of the turbocharger, drain the cooling water in
the bearing casing via two openings of the water connections.
Manual loosening
To remove the turbocharger from the bracket, proceed as follows:
u
Loosen and remove water connections. Close the openings of the water connections with
screw plugs.
u
Attach lifting gear to the suspension eye.
u
Loosen and remove nuts (C).
Hydraulic loosening (round special nut)
If the turbocharger was fitted by the enginebuilder using a hydraulic tool, disassembly is
also done using a hydraulic tool (see instructions of the enginebuilder).
When doing this, proceed as follows:
u
Attach lifting gear to the suspension eye.
u
Remove the turbocharger.
u
Cover the oil connections (03) at the engine side to protect against contamination.
Page
30
/
122
Содержание A135-H61
Страница 2: ......