-- 14 --
ba39d1ea
Fault
code
Description
8
Low battery v3 V, (welding data unit)
Battery voltage too low. If the battery is not replaced, all stored data will be lost.
This fault does not disable any functions.
Action:
Send for a service technician to replace the battery.
8
+15 V power supply, (power unit)
The power supply is too high or too low.
Action:
Send for a service technician.
9
--15 V power supply, (power unit)
The power supply is too high or too low.
Action:
Send for a service technician.
10
+24 V power supply
The power supply is too high or too low.
Action:
Send for a service technician.
12
Communication error (warning)
The load on the system’s CAN--bus is temporarily too high.
The power unit / wire feed unit has lost contact with the welding data unit.
Action:
Check that all the equipment is correctly connected.
If the fault persists, send for a service technician.
14
Communication error
The system’s CAN--bus has temporarily stopped working due to the load being too high.
The current welding process stops.
Action:
Check that all the equipment is correctly connected. Turn off the mains power
supply to reset the unit. If the fault persists, send for a service technician.
15
Messages lost
The microprocessor is unable to process incoming messages sufficiently quickly and
information has been lost.
Action
: Turn off the mains power supply to reset the unit. If the fault persists, send for a
service technician.
18
Lost contact
The welding data unit has lost contact with the power unit.
The current welding process stops.
Action
: Check the cables. If the fault persists, send for a service technician.
19
Memory error in battery--supplied data memory RAM
The battery has lost voltage
Action:
Turn off the mains power supply to reset the unit. The welding data unit is reset.
The settings are in English, with MIG/MAG, DIP/SPRAY, Fe, CO2, 1.2 mm
20
Non--permitted set values stored in RAM
Non--permitted values have been discovered at start--up. Delete all data contained in the
welding data unit.
Action:
Turn off the mains power supply to reset the unit. The welding data unit is reset.
The settings are in English, with MIG/MAG, DIP/SPRAY, Fe, CO2, 1.2 mm
21
Incompatible set values stored in RAM
Non--permitted welding data combinations have been specified.
Action
: Turn off the mains power supply to reset the unit. If the fault persists, send for a
service technician.
22
Transmitter buffer overflow
The welding data unit does not manage to transmit information to the other units
sufficiently quickly.
Action:
Turn off the mains power supply to reset the unit.