2TLC172296M0201
Rev A
2
www.abb.com/jokabsafety
2015-03-20
Safety information
Warning!
For a correct and safe use of the Orion1 Extended light curtains, the following points must be observed:
The stopping system of the machine must be electrically controlled.
This control system must be able to stop the hazardous movement of the machine within the total machine
stopping time T as per paragraph “Minimum installation distance” of the instruction manual, and during all
working cycle phases.
Mounting and connection of the AOPD must be carried out by qualified personnel only, according to the
indications included in the special sections of the instruction manual and in the applicable standards.
The AOPD must be securely placed in a particular position so that access to the hazard zone is not possible
without the interruption of the beams, see paragraph
“Installation” of the instruction manual.
The personnel operating in the hazard zone must be well trained and must have adequate knowledge of all
the operating procedures of the AOPD.
The TEST button must be located outside the hazard zone because the operator must check the hazard zone
during all the test operations.
The ACKNOWLEDGE/RESET button must be located outside the hazard zone because the operator must
check the hazard zone during all acknowledge/reset operations. It must be impossible to reach the button
from the hazard zone.
Please carefully read the instructions for the correct functioning before powering the AOPD.
Installation
Warning!
Make sure that the protection level assured by the AOPD is appropriate for the machine to be controlled,
see EN ISO 13849-1:2008.
The outputs (OSSD) of the AOPD must be used as machine stopping devices and not as command devices.
The machine must have its own Start command.
The dimension of the smallest object to be detected must be larger than the resolution of the AOPD.
The AOPD must be installed in a room complying with the technical characteristics indicated in paragraph
”Technical data” of the instruction manual.
Do not place the AOPD near strong and/or flashing light sources or similar devices.
Strong electromagnetic interferences can jeopardise the function of the AOPD. Please contact your
ABB Jokab Safety representative for advice.
The operating distance of the device can be reduced in presence of smog, fog or airborne dust.
A sudden change in environment temperature, with very low minimum peaks, can generate a small
condensation layer on the lenses and so jeopardise the function.
Reflecting surfaces placed near the light beams of the AOPD (over, under or laterally) can cause passive
reflections. These reflections can compromise the recognition of an object inside the detection zone.
The safety device must be positioned at a distance that prevents a person or part of a person to reach the
hazard zone before the hazardous motion of the machine has been stopped by the AOPD. See the instruction
manual for the calculation of this minimum installation distance.
Warning!
The minimum installation distance must be respected. For more information about its calculation,please
refer to the instruction manual or EN ISO 13855:2010.
Warning!
Make sure to test the function
and to perform the checks described in paragraph “Checks after first
installation” of the instruction manual before machine start-up.
Содержание 2TLA022303R0100
Страница 5: ...2TLC172296M0201 Rev A 5 www abb com jokabsafety 2015 03 20 Connection example to a RT9 safety relay ...
Страница 21: ...2TLC172296M3401 Rev A 5 www abb com jokabsafety 2015 03 20 Exempel på anslutning till Rt9 säkerhetsrelä ...
Страница 22: ...2TLC172296M3401 Rev A 6 www abb com jokabsafety 2015 03 20 Anslutning för OSSD utgångar JA NEJ NEJ NEJ ...
Страница 37: ...2TLC172296M0101 Rev A 5 www abb com jokabsafety 2015 03 20 Beispiel Anschluss an ein RT9 Sicherheitsrelais ...
Страница 38: ...2TLC172296M0101 Rev A 6 www abb com jokabsafety 2015 03 20 Anschluss der OSSD Ausgänge JA NEIN NEIN NEIN ...
Страница 54: ...2TLC172296M0301 Rév A 6 www abb com jokabsafety 2015 03 20 Exemple de raccordement à un relais de sécurité RT9 ...
Страница 55: ...2TLC172296M0301 Rév A 7 www abb com jokabsafety 2015 03 20 Raccordement des sorties OSSD OUI NON NON NON ...
Страница 71: ...2TLC172296M0901 Rev A 6 www abb com jokabsafety 2015 03 20 Esempio di collegamento a un relè di sicurezza RT9 ...
Страница 72: ...2TLC172296M0901 Rev A 7 www abb com jokabsafety 2015 03 20 Collegamento delle uscite OSSD SÌ NO NO NO ...
Страница 87: ...2TLC172296M0701 Rev A 5 www abb com jokabsafety 2015 03 20 Ejemplo de conexión a un relé de seguridad RT9 ...
Страница 88: ...2TLC172296M0701 Rev A 6 www abb com jokabsafety 2015 03 20 Conexión de las salidas OSSD SÍ NO NO NO ...