
IT
4
2CSYD0201B
3 INSTALLATION
The installation procedure encompasses the following steps:
1)
Device fixing.
2)
Programming
3)
Adjustment.
4)
Completion and test.
3.1
Device fixing
INSTRUCTIONS RELEVANT TO POSITIONING
The device can be installed on a wall or on a pole, far from electromagnetic sources
(e.g. electricity meters, electric engines).
The detector shall be installed:
1)
between 80 and 120 cm above the ground level (standard height 1 meter);
2)
in a vertical position, otherwise its reliability will be lower;
3)
in a way that the access is crosswise and not radial to the detector itself;
4)
by avoiding to direct IR sensors towards moving objects (e.g. swaying
trees, bushes, flags, clothes hanging, etc.);
5)
by avoiding to direct IR sensors towards reflecting objects (e.g. puddles,
windows, etc.).
6)
Figure 1 graphically summarizes the above-mentioned indications.
Figure 1
Содержание 2CSYD0201B
Страница 1: ...EN 2CSYD0201B Outdoor dual IR detector Installation manual ...
Страница 14: ...IT 14 2CSYD0201B 6 NOTES ...
Страница 15: ......