71
Technical data
EN
EVSE
Terra 60 CCT
Standards
Declaration of Conformity
CE
Low voltage Directive
EN 61851-1:2011, EN 61851-23:2014, IEC 61851-
1:2010, IEC 61851-23:2014, EN IEC 61851-1:2019,
IEC 61851-1:2017
EMC
EN IEC 61851-21-2:2021, IEC 61851-21-2:2018
RED
EN 300330 V2.1.1:2017, EN 301908-13
V11.1.2:2017, EN IEC 62311:2020, EN 50364:2018
Additional compliace with standards
1
IEC 62196-2, IEC 62196-3
Communication to the EV
DIN 70121, ready for ISO 15118 - 2 Plug’n’Charge
1. ABB uses AC cables/connectors from suppliers, who also declare compliance with this standard
10.1.2 Technical data table - Terra 360
EVSE
Terra 360 CC
Connector
Charging standard (IEC 61851-1)
Mode 4
Number of outputs
2
Number of EV served
Up to two EV in parallel
Output combinations
2x CCS 2 connectors
Cable type
Air cooled cable
Cable Length
Standard: 4.7 m
Efficiency
> 95% at nominal output power
DC Output
DC output power
360kW (peak)
DC output voltage
CCS 150...920 VDC
DC output current
Nominal 300A DC
Peak 500A DC
Overvoltage category
II
AC Input
Input connection
3 PE
Input voltage
400 Vac +/- 10%
Input frequency
50 Hz
Input Current
560 A
Input power
390KVA
Power Factor
> 0.96 @ full load
Harmonic Distortion (THD)
4.5% at full output power
Earthing systems
TN-S, TN-C, TN-C-S, TT (with upstream RCD)
Overvoltage category
III
Protection
Overcurrent, overvoltage, undervoltage, ground
fault including DC leakage protection,
overtemperature, integrated surge protection
SPD - According to EN 61643-11 and IEC 61643-11
Yes, Type 2 / Class 2
SPD - Nominal discharge current (8/20 us) [L-N] / [N-PE]
20 kA / 80 kA
SPD - Short-circuit withstand capability (ISCCR)
25 kA
Short circuit current
25 kA
Tilt sensor (option)
Voltage input
20...24 V DC
Power consumption
Max 30 mA
Reverse polarity protection
Yes