ACU-100 SATEL
17
4.5.2
LCD keypad connected to the controller
In order to add a new wireless device to the system, do the following:
1. Start the N
EW DEVICE
function.
2. Enter the 7-digit serial number of the device to be added and press the [#] key. The serial
number can be found on the electronics board or on the housing. Each radio signal level
tester has the serial number 0000500.
3. Depending on which device is to be added to the system:
−
turn on power supply of the ACX-200 or ACX-201 expander,
−
turn on the ARF-100 tester,
−
plug the ASW-100 E/ASW-100 F wireless controller into the 230 V socket,
−
install the battery in ASD-100 detector,
−
violate (open) the tamper contact in case of the other devices.
If the entered serial number is inconsistent with that of the device being added, or the
device with such serial number has already been registered, a suitable message will be
displayed and automatic return to the main menu will follow.
4. A message will confirm addition of the new device with the serial number shown on the
display. Press the [#] key to finish the procedure of adding the new device. You can
cancel the new device addition by pressing the [*] key.
4.5.3
LCD keypad of INTEGRA alarm system
In order to add a new wireless device to the system, do the following:
1. Start the function N
EW DEVICE
(
Æ
S
ERVICE MODE
Æ
S
TRUCTURE
Æ
H
ARDWARE
Æ
E
XPANDERS
Æ
S
ETTINGS
Æ
controller name
Æ
N
EW DEVICE
).
2. Enter the 7-digit serial number of the device and press the [#] key. The serial number can
be found on the electronics board or on the housing. Each radio signal level tester has the
serial number 0000500.
If a device with the entered serial number is already registered in the system, the keypad
will signal it by 3 long beeps and will fail to proceed to the next step of the procedure.
3. After the „Open device tamper” is displayed:
−
turn on power supply of the ACX-200 or ACX-201 expander,
−
turn on the ARF-100 tester,
−
plug the ASW-100 E/ASW-100 F wireless controller into the 230 V socket,
−
install the battery in ASD-100 detector,
−
violate (open) the tamper contact in case of the other devices.
If the serial number of the device to be added is different from the one previously entered,
a suitable information message will be displayed. Press the [*] key and then start the
procedure of device addition from the beginning.
4. The new device name and serial number will be displayed. Press the key 1 to proceed to
the next step of the procedure (press any other key to terminate the procedure of adding
a new device).
5. If there is an option to select one or two positions (channels) for the device in the list of
devices, a suitable message will be displayed. Press the key 1 to select one channel.
Press the key 2 to select two channels.
6. A list of system zones which can be assigned to the device will be displayed. Select one
of them (use the
T
and
S
keys to scroll the list) and press the [#] key (press the [*] key to
terminate the procedure of new device addition). If the device takes up more than one
zone in the system (e.g. AMD-101 magnetic detector, AVD-100 wireless vibration detector
and magnetic contact, ASP-105 and ASP-205 sirens, or ACX-200 and ACX-201