Publication 1738-IN002B-EN-E - November 2004

2

     ArmorPoint 24V dc Input Modules, Series A

.

Important User Information

Solid state equipment has operational characteristics differing from those of electromechanical equipment. 

Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls

 (Publication 

SGI-1.1 available from your local Rockwell Automation sales office or online at 
http://www.ab.com/manuals/gi) describes some important differences between solid state equipment 
and hard-wired electromechanical devices. Because of this difference, and also because of the wide 
variety of uses for solid state equipment, all persons responsible for applying this equipment must satisfy 
themselves that each intended application of this equipment is acceptable.
In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages 
resulting from the use or application of this equipment.
The examples and diagrams in this manual are included solely for illustrative purposes. Because of the 
many variables and requirements associated with any particular installation, Rockwell Automation, Inc. 
cannot assume responsibility or liability for actual use based on the examples and diagrams.
No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, 
equipment, or software described in this manual.
Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell 
Automation, Inc. is prohibited.
Throughout this manual we use notes to make you aware of safety considerations.

WARNING

Identifies information about practices or circumstances that can cause an explosion in a 
hazardous environment, which may lead to personal injury or death, property damage, 
or economic loss.

IMPORTANT

Identifies information that is critical for successful application and understanding of the 
product.

ATTENTION

Identifies information about practices or circumstances that can lead to personal injury or 
death, property damage, or economic loss. Attentions help you:

identify a hazard

avoid a hazard

recognize the consequence

SHOCK HAZARD

Labels may be located on or inside the equipment to alert people that dangerous voltage 
may be present.

SHOCK HAZARD

Labels may be located on or inside the equipment to alert people that surfaces may be 
dangerous temperatures.

Содержание ArmorPoint A Series

Страница 1: ...l appropriate housing I O connectors are sealed M8 pico M12 micro or M23 styles The mounting base ships with the module 0 1 2 3 4 5 6 7 MOD NET 1738 IB8M12 A 24V dc In 0 1 2 3 4 5 6 7 MOD NET 1738 IB8...

Страница 2: ...ted with any particular installation Rockwell Automation Inc cannot assume responsibility or liability for actual use based on the examples and diagrams No patent liability is assumed by Rockwell Auto...

Страница 3: ...rding specific enclosure type ratings beyond what this product provides that are required to comply with certain product safety certifications NOTE See NEMA Standards publication 250 and IEC publicati...

Страница 4: ...in the drilling dimension drawing 2 Drill the necessary holes for 8 M4 machine or self tapping screws 3 Mount the base using 8 M4 screws 4 Ground the system using the ground lug connection The ground...

Страница 5: ...Push the module down until it engages the latching mechanism You will hear a clicking sound when the module is properly engaged The locking mechanism will lock the module to the base Remove the Modul...

Страница 6: ...dules only Input 3 M12 D 1738 IB4M12 and 1738 IV4M12 modules only Pin 5 No Connect 43664 43583 view into connector Pin 1 24V dc Pin 3 Common Pin 4 Input 0 M8 A Input 1 M8 B Input 2 M8 C Input 3 M8 D I...

Страница 7: ...Message size 1 Byte 1738 IB4M8 IB4M12 and IV4M12 Modules Message size 1 Byte ATTENTION Make sure all connectors and caps are securely tightened to properly seal the connections against leaks and main...

Страница 8: ...on Indication Probable Cause Module Status Off No power applied to device Green Device operating normally Flashing Green Device needs commissioning due to missing incomplete or incorrect configuratio...

Страница 9: ...Communication faulted device the device has detected a network access error and is in communication faulted state Device has received and accepted an Identity Communication Faulted Request long protoc...

Страница 10: ...imeters 4 72H x 2 83W x 1 65D 120H x 72W x 42D Operating Temperature IEC 60068 2 1 Test Ad Operating Cold IEC 60068 2 2 Test Bd Operating Dry Heat IEC 60068 2 14 Test Nb Operating Thermal Shock 20 to...

Страница 11: ...opean Union 89 336 EEC EMC Directive compliant with EN 61000 6 4 Industrial Emissions EN 50082 2 Industrial Immunity EN 61326 Meas Control Lab Industrial Requirements EN 61000 6 2 Industrial Immunity...

Страница 12: ...automation com Installation Assistance If you experience a problem with a hardware module within the first 24 hours of installation please review the information that s contained in this manual You ca...