5
2.6.2. Configure IP by web interface
Use common Web browser, ex. Microsoft Internet Explorer or Mozilla Firefox, to configure the network
parameters of STW-602C.
Open web browser, type in the
IP address
(default IP: 10.0.50.100) of STW-602C to be
configured. Default user name is
admin
and default password is
null
(leave it blank).
Configure IP settings from web
Network links page
then click “
Save Configuration
” to save
settings.
Click on ”
Restart
” button to make the change effective.
Please refer to contents of
Web Configuration section
for more details.
.
2.6.3. Configure IP by Telnet utility
Use common Telnet utility, ex. Microsoft Hyper-terminal, to configure the network parameters of STW-602C.
Run command
telnet “IP address
” to telnet to STW-602C.
Default IP address is 10.0.50.100
and default password is
null
(leave it blank).
Configure IP settings from
network settings
menu, and
restart
system after saved settings.
Please refer to
Telnet Configuration
section for more details.
2.6.4. Auto IP with DHCP
DHCP
server will automatically supply an
IP address
gateway address
, and
subnet mask
to STW-602C.
By default, the DHCP client function on STW-602C is disabled, user can activate the DHCP functions by the
following steps
Execute
SerialManager Utility
Click on the
IP address
(of STW-602C)
Click “
Config
” to pop-up the static IP Dialog Window
Check on ”
Auto IP
”
Click “
Config Now
” (The STW-602C will restart and obtain the IP from the DHCP server
automatically)
2.7. TCP/IP Port Number
Default Port numbers of STW-602C is
4660
(1
st
port) &
4661
(2
nd
Port) and it is associated with the serial port
COM1
and
COM2
respectively. After the application program connected to the TCP port 4660 (or 4661) on
the STW-602C, data of user’s application program are transmitted transparently to STW-602C and vice
versa.