background image

OpenCom 150 – OpenCom 150

OpenCom 150 Rack – OpenCom 150 Rack

OpenCom 130 – OpenCom 130

OpenCom 510 – OpenCom 510

Cascading Set: Scope of Delivery

Installation Notes 

Open Com 130 – OpenCom 130: Earth Connection

OpenCom 100 Cascading 

Short Installation Guide

Item No.: 41-001294-00
As of December 2008
© Aastra Telecom Schweiz AG • http://www.aastra.de

1-12 frame: master system

1-12 frame: slave system

PCM port of the central control module MC+1-3: 
voice and administration data lead

PCM

PCM

C

Master system

LAN0 LAN1

PCM1 PCM2

Slave system

LAN0 LAN1

PCM1 PCM2

PCM1:   voice data lead
LAN1:   administration data lead

Note:

 For the OpenCom 150 

(wall version), the availablity 
of the required ports depends 
on the hardware version.

B

B

S2M/PRI

Slave system

PCM1

PCM2

LAN0

LAN1

S2M/PRI

Master system

PCM1:   voice data lead
LAN1:   administration data lead

PCM1

PCM2

LAN0

LAN1

B

B

Master system

Slave system

PCM1:   voice data lead
LAN2:   administration data lead

Connect earth to 

both

 PCM ports:

1. 

Connect cable A to PCM ports.

2.

  Connect earth (to each PCM port).

PCM

LAN1

LAN2

LAN0

LAN1

LAN2

LAN0

PCM

earth connection
required!
(see figure left)

A

B

Licence

Short installation
guide

length: 2 m, with 
earth connection

length: 2 m

length: 0.5 m

4 CAT5 Ethernet STP patch cables:

Fastening set
for cable A:

2 screws,
2 lock washers

A

B

C

2x

PBX cascading may only be carried out by 
qualified experts. Please also follow the 
safety instructions in the OpenCom's 
“Mounting and Commissioning” guide.

Caution!

 Static charge can damage electronic 

devices. Observe the regulations regarding 
electrostatically sensitive components!

 

Danger!  Dangerous voltage in device!

 

 

Disconnect master and slave system 

 

 

from the mains supply!

 

 

With an OpenCom 510:

 

 

If a 1-12 frame is being powered by 

 

 

two power supply units, pull 

both

 

 

 

mains plugs out of the power socket!

Other valid documentation 

This short installation guide is only valid with the “Mounting and Commissioning” guide which 
is included, in the form of a PDF file, on the OpenCom 100 product CD. The latest version of the 
“Mounting and Commissioning” guide is also available on the Aastra website. You can download 
it from the password-protected partner area: 

https://portal.aastra-detewe.de

.

For detailed information on PBX Cascading, please refer to the “PBX Cascading” chapter
in the “Mounting and Commissioning” guide. 

Licence information

For the PBX Cascading you will need a licence. 
The licence agreement (included in the cascading set's scope of delivery) provides you with 
the necessary steps to activate this function.

Safety instructions

Отзывы: