Ascotel® IntelliGate® 150/300 as of I7.9
Installation
67
sy
d-
021
0/1.
7
– I7.
9 – 1
2.
2009
4. 2. 7
Rack-mounted installation
The rack-mounting set A150 or A300 allows the system to be installed horizontally
into a 19” rack. Be sure to observe the following:
•
The system takes up the space of 1.5 height units (units) inside the 19” rack.
(1 unit corresponds to 44.45 mm).
•
The holes in the mounting plates allow two systems to be placed directly above
each other with a space requirement of three units. Different holes in the mount-
ing plates are used for this purpose (see
•
The space on the left and right between the system and the panels of the 19”
rack is for heat dissipation and must remain clear.
•
The installation of a fan is compulsory when rack-mounting an A300; the fan is
included in rack-mounting set A300.
Note: The set of screws for rack mounting always includes fastening screws for
the fan. On the A150 these two screws are superfluous.
Fig. 20
Placing two systems above each other inside a 19” rack