Ascotel® IntelliGate® 150/300 as of I7.9
206
Operation and Maintenance
sy
d-
021
0/1.
7
– I7.
9 – 1
2.
2009
The Event Log consists of four protocols:
•
Event messages (max. 254 entries)
•
System failures (max. 80 entries)
•
Power failures (max. 10 entries)
•
Card failures (max. 150 entries)
If the maximum number of entries is exceeded, the oldest entry in each case is de-
leted.
These 4 Event Logs protocols are not printed out automatically; likewise, your at-
tention is not drawn to any incoming event message. The protocols have to be re-
trieved manually in the Fault & Maintenance Manager or printed out.
See also:
Event messages entered in the protocols of the Event Logs can also be
retrieved on the Office 45 using the System Assistant function on
Office 45 (see
"Maintenance menu on the Office 45", page 209
).
Testing the signal destination configuration
To test the configuration, you can trigger a test event message via the Fault & Main-
tenance Manager. The event message is signalled without any delay, directly at the
selected signal destination.
If the PBX is connected with AIMS via a TA, the test event messages will be signalled
only once the connection is cleared down.
6. 6. 1. 4
SNMP destination
5 SNMP destinations can be defined. These destinations are linked with the same
event table as the local destination, and so the same rules are applied. Forwarding
to the SNMP destinations can be activated and deactivated independently of the
forwarding to the local and external signal destinations.
For configuration in the Fault & Maintenance Manager proceed as follows:
1.
In the tab "
SNMP destination
" enter the IP address under "
IP address/host name
"
(or the host name if DNS is configured)
2.
Configure the remaining parameters